AUTO Mode: 

The humidistat will automatically raise the humidity as the outdoor temperature 

increases. This provides the highest possible humidity. The humidistat will automatically lower 
the humidity as the temperature drops. This minimizes the risk of condensation on cold sur-
faces like windows.

 

In AUTO mode only, the Auto Humidity Index Set Point may be changed. 

You can set your desired humidity index from 0 (low) to 10 (high) by pressing 

UP

 or 

DOWN

The Humidity Index is based on the outdoor temperature and indoor humidity. The humidi-
fier will switch ON/OFF according to the calculated auto humidity index set point. When the 
humidifier is operating, the     will display. Lower Index settings are for older homes with less 
insulation and poor vapor barriers. Higher Index settings are for newer homes with complete 
vapor barriers, triple pane windows and high R value insulation.

Humidity  Dwelling Type

  Index

  1-2 

Older than 1950, no vapor barrier, little insulation.

  3-4 

Built 1950-1965, no vapor barrier, R6 insulation.

  5-6 

Built in 1965-1975, craft vapor barrier, R11 insulation.

  7-8 

Built in 1980-1990, craft vapor barrier, R19, double pane windows.

  9-10 

Built after 1990, poly vapor barrier, R38 insulation, foam exterior cladding, triple  

   

pane windows.

If condensation is seen or suspected, reduce humidity index by 2 until condensation stops. 
The level bars in the upper right portion of the display indicate the humidity index; one bar for 
every two index points. For example, a humidity index of 6 will have three bars displayed in 
the upper right corner of the display.

AUTO Mode Target Humidity

OFFSET Mode

To change the calibration of the humidistat, an offset may be entered to the Humidity, Indoor 
Temperature or Outdoor Temperature displays. Press both 

UP

 and 

DOWN

 buttons together to 

enter OFFSET mode. The word OFFSET and RH will display. Press 

UP

 OR 

DOWN

 to change the 

humidistat’s Humidity calibration. Press both 

UP

 and 

DOWN

 buttons together again to change 

the Indoor Temperature offset. Press both 

UP

 and 

DOWN

 buttons together again to change 

the Outdoor Temperature offset. 

Display a Temperature

Press the 

THERMOMETER

 button to move between displaying indoor and outdoor 

temperature. The “tree” symbol will be displayed when showing outdoor temperature (if 
outdoor sensor is connected). The “house” symbol will be displayed when showing indoor 
temperature. To change between ˚F and ˚C, press the 

˚F / C˚

 button.

Trouble Shooting

   

“house” symbol flashing: 

The indoor temperature sensor has failed.

         
         “tree” symbol flashing

: The outdoor temperature sensor has failed.

Humidifier Turns On and Off Repeatedly

  - Check that input voltage is between 18 and 30 volts AC and not intermittent.
  - Check that humidistat is NOT mounted on supply duct, downstream of the humidifier
    or within 12 inches of the humidifier.
  - Make sure that Outdoor Sensor wiring is not close to line voltage wires.

Humidifier Runs Continuously

  - If humidifier operates while HVAC system is off, check that power to humidifier is 
    switched with HVAC operation.
  - If humidifier operates every time HVAC system runs, compare humidity to set point. If  
    humidity is lower than set point, humidistat will call for operation.

Humidifier Does Not Run

  - Check wiring to / from humidistat control. Verify 18-30 volts. Use TEST MODE (see
    “Testing the System”).

Humidifier Runs When Air Conditioning is On

  - If this is undesirable, change wiring to be powered only during heating periods, or set
    humidistat to Off mode.

Humidity Not High Enough

  - Fault with humidifier. Check humidifier, water supply, electrical connections.
  - HVAC operating time is too short. Check humidifier trouble shooting.
  - Humidifier is undersized. Review humidity load and humidifier capacity.
  - Humidity index is set too low in Auto Mode (see “Auto Mode”).

Humidity Too High

  - Wiring fault. Set humidistat to “OFF” mode and check that operation ceases.
  - Outdoor sensor is being kept warm. Check that sensor is not buried in snow, on south  
    side of house being warmed by sun or is too far inside of air intake.
  - Humidity index set too high for structure.

WARRANTY FACILITY: 

Braeburn Systems LLC

 

 

Attn: Warranty Department

 

 

2215 Cornell Avenue

 

 

Montgomery, IL 60538

5

YEAR

 

WARRANTY

LIMITED

Five Year Limited Warranty

Braeburn Systems LLC 
2215 Cornell Avenue • Montgomery, IL 60538
Technical Assistance: www.braeburnonline.com
Call us toll-free: 866-268-5599 (U.S. Only)
630-844-1968 (Outside the U.S.)

©2009 Braeburn Systems LLC • All Rights Reserved • Made in China  
229150-100-002

Outdoor Temperature °F

 

-20

-10

0

10

20

30

40

50

1

0

5

10

15

20

25

30

35

2

0

8

13

18

23

28

33

38

3

0

11

16

21

26

31

36

41

4

0

14

19

24

29

34

39

44

5

0

17

22

27

32

37

42

47

6

0

20

25

30

35

40

45

50

7

0

23

28

33

38

43

48

53

8

0

26

31

36

41

46

51

56

9

0

29

34

39

44

49

54

59

10

0

32

37

42

47

52

57

62

Humidity

Index

Testing the System

1.  Re-assemble system and check all connections.
2.  Restore power to the HVAC system.
3.  Check to see that humidistat display is on. 
4.  Start HVAC System by raising thermostat setting in heat mode. 
5.  Set humidistat to TEST MODE by pressing the 

DROP

 and 

THERMOMETER

 buttons at the 

  same time for 5 seconds. The relay will close and the      will flash for 2 minutes. The  
  humidifier should start operation.
6.  Set to OFF mode to verify humidifier operation ceases.
7.  The humidistat will stay in OFF mode unless set to Manual or Automatic mode. See “Operation”.

Operating Modes

Press any button to light the display. Press the 

DROP

 button to select Off, Manual or Auto Mode.

 

OFF Mode: 

The humidifier is turned off. 

MANUAL Mode: 

The humidistat will maintain the single humidity 

set point selected. You can set your desired humidity level by
pressing 

UP

 or 

DOWN

. The humidifier will turn ON or OFF 

according to your setting. The humidifier will operate when the 
measured relative humidity falls more than 1% below the set
point until the measured relative humidity is 1% above the 
set point. When the humidifier is operating, the     will appear in 
the display. Humidity may have to be lowered when weather is 
colder or if condensation is suspected. The settings table at right 
may be used for manual humidistat control.

 

 

Outdoor   Suggested

Temperature  Setting

 -20˚F  -29˚C 

15%

 -10˚F  -23˚C 

20%

   0˚F  -18˚C 

25%

+10˚F  -12˚C 

30%

+20˚F    -7˚C 

35%

+30˚F   -1˚C 

40%

% Relative Humidity

Braeburn Systems LLC warrants each new Braeburn digital humidistat against any defects 
that are due to faulty material or workmanship for a period of five years after the original 
date of purchase by a professional service technician. This warranty and our liability does 
not include damage to merchandise or the humidistat resulting from accident, alteration, 
neglect, misuse, improper installation or any other failure to follow Braeburn installation 
and operating instructions.
Braeburn  Systems  LLC  agrees  to  repair  or  replace  at  its  option  any  Braeburn  digital 
humidistat under warranty provided it is returned postage prepaid to our warranty facility 
in a padded carton within the warranty period, with proof of the original date of purchase 
and a brief description of the malfunction. This limited warranty does not include the cost 
of removal or re-installation.
This warranty gives you specific legal rights and you may also have other rights that vary 
from state to state or province to province. Answers to any questions regarding our limited 
warranty may be obtained by writing our corporate offices.

Reviews: