Bradley WC7180 Installation Download Page 3

Installation

WC7180

3

Bradley Corporation • 215-326 Rev. G; EN 08-705

7/15/09

Rough-Ins

Supplies Required:

• (6) 1/2"-13 threaded studs

• 1-1/2" NPT supply piping to flush valve

• Waste connection

17" (432mm)

TOP OF

INTEGRAL

TOLIET SEAT

FIXTURE MOUNTING WITH SLEEVE

10" (254mm)

3" (76mm)

8"

(203mm)

SQUARE

4" (102mm) SQUARE

7/8" (22mm) DIA.
(6) HOLES

20"

(508mm)

WALL

OPENING

2" (51mm)

FINISHED FLOOR

FINISHED FLOOR

6"

(152mm)

12"

(305mm)

18-1/2"

(470mm)

13-1/4"

(337mm)

18-1/2"

(470mm)

13-1/4"

(337mm)

7"

(178mm)

41"

(1041mm)

11"

(279mm)

13-1/4"

(337mm)

5"

(127mm)

5-1/4"

(133mm)

FINISHED FLOOR

Back Supply 
1-1/2

"

 (38mm) Dia. for Mech. Push Button

2

"

 (51mm) Dia. for Hyrdaulic 

or TouchTime Push Button

Summary of Contents for WC7180

Page 1: ... accounted for before discarding any packaging material If any parts are missing do not begin installation until you obtain the missing parts Before installing components all connection supply lines must be flushed and free of foreign material such as pipe dope chips solder etc Bradley will not be responsible for leaking valves due to the presence of foreign material or distorted stop gaskets wher...

Page 2: ...ley Corporation 215 326 Rev G EN 08 705 Dimensions 14 356mm 14 3 4 375mm 22 3 4 578mm FINISHED FLOOR 5 18 457mm 3 4 19mm STANDARD INTEGRAL SEAT HEIGHT IS 17 432mm OPTIONAL PLASTIC SEAT HEIGHT IS 18 1 2 470mm TO TOP OF PLASTIC SEAT 127mm ...

Page 3: ...TOLIET SEAT FIXTURE MOUNTING WITH SLEEVE 10 254mm 3 76mm 8 203mm SQUARE 4 102mm SQUARE 7 8 22mm DIA 6 HOLES 20 508mm WALL OPENING 2 51mm FINISHED FLOOR FINISHED FLOOR 6 152mm 12 305mm 18 1 2 470mm 13 1 4 337mm 18 1 2 470mm 13 1 4 337mm 7 178mm 41 1041mm 11 279mm 13 1 4 337mm 5 127mm 5 1 4 133mm FINISHED FLOOR Back Supply 1 1 2 38mm Dia for Mech Push Button 2 51mm Dia for Hyrdaulic or TouchTime Pus...

Page 4: ...e supply pipe to the 1 1 2 NPT inlet half coupling on the back of the unit TOP SUPPLY Connect the flush valve supply pipe to the 1 1 2 NPT inlet half coupling on the top of the unit B Slide the studs and pipe through the wall openings and position the unit into place Secure the unit to the wall using the nuts 110 119 washers 142 002AM and brackets 140 277 provided Fasteners must be securely tighte...

Page 5: ...ective coating the helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance to the manufactures instructions and in the direction of the polish lines Precautions Avoid prolonged contact with chlorides bleaches salts bromides sanitizing agents thiocyanates pesticides photography chemicals and some ...