LVSD2
Installation
6
9/1/2022
Bradley
• 215-1829 Rev. E: ECO 22-08-005
Mounting for Standard, ADA, and TAS height shown.
Structural Rough-Ins
(mm)
Points A, B, and C require sufficient backing
compliant with local building codes.
Secure bracket to wall using min. (2) 3/8" anchor bolts to
the left of C/L and min. (2) 3/8" anchor bolts to the right of
C/L. The (2) anchor bolts to the right of C/L must be min.
16" apart from the anchor bolts to the left of C/L. When
mounting is complete, check to ensure the bracket is level.
See Step 1: Bracket Mounting for more information.
33½"
(851)
A
A
25½"
(648)
29½"
(749)
B
B
20"
(508)
CL
16¾"
(425)
31
⁵⁄₈
"
(803)
20"
(508)
17
⁵⁄₈
"
(446)
16½"
(419)
16½"
(419)
17
⁵⁄₈
"
(446)
Finished Floor
C
C
WARNING The bracket is not designed to support the bowl. Wall bracket
is a temporary support until bowl is mounted at location "A".
Ensure bowl is completely seated in the wall bracket and
securely fastened to the wall at point A.
24"
(610)
24"
(610)
D
D
3/4"
(19)
17¾"
(452)
CODE
DESCRIPTION
QTY.
A
Install (1) 3/8" wall anchor with a minimum pull-out force of 1,000 lb per local codes at locations shown.
2
B
Provide structural backing compliant with local building codes.
2
C
Install wall anchor with a minimum pull-out force of 100 lb per local codes at locations shown for fold-up access panel option.
2
D
Install wall anchor with a minimum pull-out force of 100 lb per local codes at locations shown for swing-down access panel option.
4
RIM HEIGHT
VERTICAL HEIGHT ADJUSTMENTS
FIXTURE STYLE
33½"
No Adjustment
Standard Height, ADA, TAS, and CSA
30½"
Subtract 3"
Juvenile, ADA, and TAS
32½"
Subtract 1"
AODA
33"
Subtract ½"
OBC