background image

SXWS9148FM, HSC91   

Installation

2

 

3/1/2013

 Bradley 

• 215-1360 Rev. G; ECN  13-10-005

Dimensional Information

Installation

(mm)

42-5/8"

(1083)

24"

(610)

13"

(330)

44"

(1118)

11-5/8"

(295)

33-1/8" (841) 

to Finished Floor

72" (1828) 

to Finished Floor

42" (1064) 

to Finished Floor

SXWS9148FM shown. 

Rough-ins same for HSC91.

Wall Opening

A

Using the hex key (taped to the shower 

panel), remove the ten security screws 

from the shower panel and remove the 

frame from the panel.

B

Install the frame into the wall 

opening per the instructions 

included with the frame.

E

Reattach the panel to the frame 

with the ten security screws.

C

Install the control buttons per 

instructions included with the 

valve assembly. Apply 100% 

silicone caulk to escutcheon 

backside prior to installation 

to ensure a water tight seal. 

Wipe excess caulk from 

front side of escutcheon and 

panel.

D

Install the valve assembly and make the 

valve connections to the showerhead 

and control buttons per the instructions 

included with the valve assembly.

Minimum Wall Depth:

Frame Only =  2.0" (51)

ASTM = 4-1/2" (114)

TTST=3.0" (76)

WARNING! After installation, all joints require security 

sealant by installer to eliminate gaps (if present) 

between wall and fixture.

F

Ensure proper shower head 

adjustment and tightening of 

screws.

Reviews: