Ligature Resistant Showerhead

 Installation

7/2/2013 

Bradley • 

215-1780 Rev. B; ECN 13-03-009

Supplies Required:

•  Security Sealant
•  1/4" Tamper Resistant Button Screws with Security Pin (4)
•  Anchors for 1/4" Screws (4)
•  Water supply piping to connect 1/2" NPT

Rough-in

1

A

Rough-in the supply piping as 
required for your installation.

Finished Wall

1/2" NPT 

Female

Install Showerhead

2

A

Determine mounting location. 
Use showerhead as template 
to mark the four mounting hole 
locations.

B

Install wall anchors (supplied 
by installer) for 1/4" screws 
at the marked anchor hole 
locations.

C

Secure the showerhead to the 
wall anchors with 1/4" screws 
(supplied by installer).

E

D

Apply security sealant 
completely around  
showerhead after installation.

Ensure proper shower head 
adjustment and tightening of 
screws.

WARNING!  After installation, all joints require security 

sealant (by installer) to eliminate gaps (if 