Step 1: Assemble Eyewash
1. Assemble the eyewash to the tank outlet with
pipe sealant (by installer) (see page 5).
IMPORTANT: When connecting the
eyewash to the tank outlet, hold the
adapters (items 2 and 3) with a wrench
to prevent stripping. Failure to do
so may damage the seal and cause
leakage. Max. torque 150 in-lbs.
2. Connect the pressure gauge to the adapter
on the pressure side of the tank with pipe
sealant (by installer) (see page 5).
Step 2: Assemble Heater Jacket
1.
Secure the pipe insulation and jacket to the
eyewash.
2. Wrap the belt around the tank four inches
from the bottom of the tank; fasten securely.
3. Connect the heat trace cable to the junction
box.
4. Slide the jacket up the side of the tank and
pull the drawstring at the top of the jacket.
5. Place the junction box in the pocket on the
inside of the jacket.
Step 3: Fill tank and pressurize
1.
If the tank is pressurized, relieve the tank
pressure by pulling up on the relief tank tab
in the center of the cover until the pressure
gauge reads “0.”
IMPORTANT: DO NOT open the cover
until the pressure gauge reads “0.”
2. Open the tank by pulling up on the wire
handle located on top of the Quicklock
cover. Push down, rotate and remove. Fill
the container with 7 gallons of potable water.
Replace the cover.
3. Pressurize the tank to 95 PSI by applying air
pressure to the tank valve located beneath
the pressure gauge.
NOTE: Relief valve is designed to automatically
vent at 100-130 PSI to prevent the tank from
overpressurizing.
Step 4: Flush tank
1.
Discharge the water through the eye wash
and hose spray to flush the system.
2. Refill the tank and pressurize as explained in
Step 3 outlined above.
NOTE: Let unit stand for one hour. If there is a
noticeable pressure drop, repressurize and let
stand for one hour. If problems persist, consult the
Troubleshooting guide found on page 4.
NOTE: This unit will provide at least 15 minutes
of cleansing action. Take the injured person
immediately to a normal emergency station for
additional cleansing and treatment.
3. Plug the heater jacket’s electrical cord into an
electrical outlet.