Installation

 LVAD2

Bradley 

• 215-1850 Rev. A; ECN 17-08-002 

4/17/2017 

3

Components

LVAD2BO

Contact your Bradley 

Representative for color options

Individual Rough-In Option

Chrome P-trap (S29-094)

Plastic P-trap (269-1697)

O-Ring 

(125-111)

Drain 

Adapter

Packing 

Washer

#10-24 

Screw

Drain 

Adapter 

Prepack

(S45-2480)

Access Panel 

(186-1912)

Wall Bracket 

(140-1128)

Drain Cap 

(111-140)

Drain Cap Spacer 

(269-2540)

Trough Strainer  

(173-039)

Trough Strainer Screw

(160-353)

Access Panel Bracket 

(140-1172)

#10 Access Panel 

Thumb Screw  

(160-536)

Access Panel Security 

Screw Option 

(S45-2880)

 TMV Valve 

(1/2"  NPTM 

Outlet)  

(S45-2701)

 Hose Prepack 

(S45-2730)

 Supply 

Fittings 

(S45-2510)

TMV Supply 

Connections

Plastic Hose

 Supply Fittings 

(S45-2511)

 Hose Prepack  

(S45-2731)

Tempered Supply 

Connections

Plastic 

Hose

Plastic Hose

Stainless 

Steel 

Hose

Summary of Contents for LVA Series

Page 1: ...ge 1 of 13 4 17 2017 LVAD2 Verge Wash Basin LVA Series with Evero Natural Quartz Material Table of Contents Components 3 4 Supplies Required 5 Dimensions 5 6 Rough Ins 7 8 Overflow Plug Assembly 9 Dra...

Page 2: ...minimum pull out rating of 1 000 pounds IMPORTANT Read this entire installation manual to ensure proper installation When finished with the installation file this manual with the owner or maintenance...

Page 3: ...2480 Access Panel 186 1912 Wall Bracket 140 1128 Drain Cap 111 140 Drain Cap Spacer 269 2540 Trough Strainer 173 039 Trough Strainer Screw 160 353 Access Panel Bracket 140 1172 10 Access Panel Thumb S...

Page 4: ...r Optional Transformer Plug In Transformer Option PT for IR DCD Faucet S53 337 Plug in transformer option PT includes Transformer S53 338 Adapter S53 339 and Grounding Kit S53 349 for CAP DCA Faucets...

Page 5: ...el brackets minimum pull out rating of 100 lbs hot cold or tempered stub out 1 NPT drain stub out s OPTIONAL 2 110 volt GFCI protected electrical outlets for 100 120 VAC plug in transformers only Scre...

Page 6: ...14 357mm 3 3 4 95mm C 20 508mm 21 534mm 20 7 1 2 190mm 7 1 2 191mm 2 50mm ADA TAS Standard Height ADA TAS Juvenile Height Children 6 12 years CSA Standard Height Dim A 33 1 2 851mm 30 1 2 775mm 33 1...

Page 7: ...C Install wall anchor with a minimum pull out force of 100 lbs per local codes at locations shown 4 Wall Bracket RIM HEIGHT VERTICAL HEIGHT ADJUSTMENTS FIXTURE STYLE 33 No Adjustment Standard Height A...

Page 8: ...nting for Standard ADA and TAS height shown mm 33 1 2 851 24 1 8 613 17 1 2 444 Min A E H C C L 2 1 4 57 1 25 Finished Floor 25 635 4 1 2 114 E CODE DESCRIPTION QTY A 1 NPT Drain Stub out 2 from wall...

Page 9: ...nsions For ease of drain installation lay the bowl on its back 2 Drain Assembly Install wall bracket to wall per structural rough in dimensions Check to ensure the bracket is level Example anchor loca...

Page 10: ...l flange into the wall bracket lip Ensure bowl is level A Secure the bowl to the wall anchors using fasteners per the structural rough in requirement supplied by installer B WARNING Ensure bowl is com...

Page 11: ...to ensure delivery of a safe water temperature Water in excess of 110 F 43 C may cause scalding 6 1 station shown 2 station similar Strainer and Drain Cap 5 Position drain cap over trough strainer ali...

Page 12: ...orizontal position is open B Hang access panel onto mounting brackets attached to wall on the left and right sides Rotate panel up and check fitup between thumbscrews and panel slots Rotate access pan...

Page 13: ...ns and always use a soft cloth or sponge to avoid damaging the finish Stubborn Stains To remove stains from stainless steel use a stainless steel cleaner and polish such as Ball stainless steel cleane...

Reviews: