Bradley Aerada 1000 Series Installation Instructions Manual Download Page 4

Aerada 1000/1100 Series 

Installation

4

 

5/21/08

 Bradley 

Corporation

 • 215-1628 Rev. A; EN  08-201

INSTALLATION

This faucet comes with all the components needed for installation,however, some 
tools and supplies are not included.

•  Basin Wrench

•  Adjustable Wrench

•  Adjustable Locking Pliers

•  Plumber´s Putty

•  Hex Key (supplied)

•  Outlet Key (supplied)

 

  Do not use pipe dope on faucet and supply connections. Possible 
solenoid contamination could occur and will void any warranty.

Mounting of Lavatory and Gooseneck Faucet

 Prerequisites

•  Supply valve is installed

•  Water supply lines are fl ushed properly

•  For AC faucets, power outlet is installed
 

 

 

 It is not necessary to unscrew the connection between braided hose 
and housing to install the product.

 

 

 

 Do not remove protective covering from sensor until starting up faucet 
operation.

 

 

 

Do not tighten locknut before step 4 is completed.

1  

Mount cover plate if required. Plumber´s putty is recommended to seal the 
cover plate to the sink. Security pin must be located on the left side.

2  

Mount gasket and put faucet into sink.

3  

Mount bracket from underneath. Place hoses through large opening and 
mounting rod through small opening. Make sure fl ange sits securely against 
surface.

4  

Place nut onto mounting rod and tighten with wrench.

5  

If faucet was installed with cover plate, secure with basin washer, fl at washer 
and locknut.

6  

Install aerator and tighten with aerator key (supplied).

7  

For Gooseneck faucets, tighten spout with wrench.

8   

Connect braided hose with fi lter to supply valve 

 

 

 

Cold water > white label     Hot water > no label

   

 

For AC faucets, please refer to the plugin or hardwired transformer 
installation instructions.

9  

Connect to power supply.

Result: 

The faucet is now mounted.

Summary of Contents for Aerada 1000 Series

Page 1: ...fore beginning installation Do not use pipe dope Debris in supply lines can cause valves to malfunction Product warranties may be found under Products on our web site at www bradleycorp com Installation TH IS SIDE UP Packing List P O Box 309 Menomonee Falls WI 53052 0309 Phone 1 800 BRADLEY Fax 262 253 4161 www bradleycorp com Installation 215 1628 Rev A EN 08 201 2008 Bradley Corporation Page 1 o...

Page 2: ...with during handling of this product Make sure there is enough space and lighting available during installation and service Do not modify or convert this Faucet any modifications will void warranties Installation may be performed at different times of construction by different individuals For this reason these instructions should be left on site with the facility or maintenance manager Pressurized...

Page 3: ...943 Filter only 269 1948 10 Deck Mounting Hardware Kit 269 1949 11 Electronics Module Kit 269 1941 12 Solenoid Valve 269 1940 COMPONENT PARTS Aerada 1000 Series Gooseneck Components Bradley Part Nos 1 Spout 269 1958 2 Shut Off Screw Assembly 269 1944 3 Outlet Assembly Kit Spout 5 GPM 269 1947 4 Gooseneck Base without opening 269 1959 5 6 V Lithium Battery CR P2 261 010 6 AC Adaptor Kit 269 1942 7 ...

Page 4: ...ive covering from sensor until starting up faucet operation Do not tighten locknut before step 4 is completed 1 Mount cover plate if required Plumber s putty is recommended to seal the cover plate to the sink Security pin must be located on the left side 2 Mount gasket and put faucet into sink 3 Mount bracket from underneath Place hoses through large opening and mounting rod through small opening ...

Page 5: ...l items from sink 3 Remove protective covering from sensor 4 Wait for 15 seconds for the faucet to calibrate to its environment Result The faucet is now activated 15 sec Test Function 1 Hold hand in front of sensor Water flow starts WARNING Hot water may burn your skin Hold hand carefully under water and remove quickly 2 For faucets with external mixer turn mixer handle from cold to warm Water tem...

Page 6: ...be saved Prerequisites Water supply valve is open Battery is full LED does not blink for DC faucets AC power is on for AC faucets 1 Remove shut off screw 2 Remove mixer handle only for faucets with external mixer 3 Remove housing vertically 4 Remove battery from battery holder 5 The following procedure a b c must be done three 3 times in a row a Re insert battery b LED lights up c Remove battery i...

Page 7: ...Mode Setting the normal mode will allow the faucet to activate only when it senses a hand presence 1 Enable Manual Setting Mode See Enabling Manual Setting Mode section 2 Fully cover sensor with hand Water flow stops after 5 seconds Continue to hold on for one 1 additional water pulse 3 Remove hand Result Normal Mode is now activated C Setting Metering Mode 10 seconds Setting the metering mode wil...

Page 8: ...additional water pulses 3 Remove hand Result Scrub Mode is now activated for 180 seconds F Sensor Range Adjustment The detection distance of the sensor can be adjusted between approximately 4 11 inches from the infrared window 1 Enable Manual Setting Mode See Enabling Manual Setting Mode section 2 Remove all items from the sink 2 Fully cover sensor with hand Water flow stops after 5 seconds Contin...

Page 9: ...erating Modes Description A Cleaning Mode The faucet is inactive for 90 seconds B Normal Mode The faucet is activated if it senses a hand presence This is the default operating mode of the faucet C Metering Mode 10 s The faucet will shut off after 10 seconds regardless of hand presence detected D Scrub Mode 60 s The faucet will shut off 60 seconds after the detection of the last hand presence E Sc...

Page 10: ...r Power adapter contacts are corroded AC faucets only Clean contacts Connecting cable is kinked or broken AC faucets only Replace defective parts See Replacement Parts No external power supply AC faucets only Check external power supply Provide power supply Shut off screw is missing or defective Replace shut off screw See Replacement Parts Solenoid valve inoperable Replace solenoid valve See Repla...

Page 11: ... or scratched Clean window with smooth cloth Input line pressure fluctuates Install appropriate line pressure regulators Faucet is leaking water Connections between housing and braided hoses are loose Check O rings Replace O rings when damaged or missing Connection between braided hose and inlet supply are loose Check rubber washers Replace washers when damaged or missing Connection between valve ...

Page 12: ...Setting mode See Manual Setting instructions When cleaning mode is activated the faucet will be inoperable for 90 seconds 1 Fully cover sensor with hand until water flow stops This takes approximately 5 seconds 2 Remove hand Result Cleaning Mode is now activated Replacing Battery A traditional lavatory faucet is shown as an example These instructions apply to all DC models Prerequisites Battery is...

Page 13: ...d water white label Hot water no label Result The filter is now cleaned or replaced Adjusting Hot Water Limiter External Mixer The proportion of hot water can be switched from approximately 85 to 95 or reverse depending upon inlet water pressures and temperatures The default setting is 85 WARNING Hot water may burn your skin Hold hand carefully under water and remove quickly 1 Remove mixer handle ...

Page 14: ...lace aerator then reinstall 3 Install shut off screw Result The aerator is now cleaned or replaced Multi Faucet Transformer Installaion 232 009 1 8 faucets Transformer can be used to connect up to 8 faucets All units must be connected in parallel AC CONNECTOR FROM FAUCET BANK INSTALLATION ADAPTER WIRE BANK INSTALLATION ADAPTER WIRE INCL W AC FAUCET ADDITIONAL WIRING IF NEEDED TO BE SUPPLIED BY CUS...