P
a
g
e
4
UPDX
Series
Introduction
The new Bradford White UPDX2 water heaters are designed to provide reliable performance
with enhanced standard features
.
New design features include reliable spar
k
to pilot ignition
system, enhanced diagnostics, simplified servicing, significantly quieter operation, additional
vent lengths, certified FVIR technology and Ultra Low NOx emissions
.
S
pa
r
k to P
i
lot Ign
i
t
i
on
S
y
s
t
e
m
- E
mploying the spar
k
to pilot ignition system promotes
reliable and consistent pilot and main burner ignitions to provide hot water on demand
.
Int
e
g
r
at
e
d Imm
ersi
on Th
er
mo
s
tat/Ga
s
Cont
r
ol Valv
e
w
i
th LED
-
Was developed for ease
of troubleshooting by providing simple diagnostic codes to pinpoint an installation or
component performance issue
.
Pow
er
ful Blow
er
-
Will eliminate problems with difficult venting situations
.
Qu
ie
t
er
and Cool
er
Blow
er
Op
er
at
i
on
-
Blower noise is significantly reduced for both
interior and exterior environments
.
Cooler operation increases blower life by reducing bearing
wear and noise
.
Rugg
e
d W
iri
ng Conn
e
ct
i
on
s
-
Receptacle type connections promote error free wiring
.
Inc
re
a
se
d V
e
nt L
e
ngth
s
-
Increased venting performance is achieved while maintaining
E
nergy Factor & First Hour Supply performance
.
The UPDX2 water heaters use a combustion system where flue gases are combined with
dilution air to reduce the flue gas temperature in the blower, combustion air and dilution air are
drawn from outside the building
.
The diluted flue gases are evacuated to the exterior through
low temperature vent materials
.
The gas control maintains water temperature, ignition
sequence and regulates gas flow
.
A safety circuit consisting of a pressure switch and blower
temperature switch verifies proper conditions exist for safe and reliable operation
.
If a situation
outside of normal operating parameters exists, the gas control diagnostic L
E
D will flash a code
to identify an operational issue
.
This service manual is designed to facilitate problem diagnosis and enhance service efficiency
.
To further promote quic
k
er service times the new gas control can be removed and replaced
without draining the water heater
.
A special tool is required and will be provided with each gas
valve
k
it shipped from our Service Parts department
.
Please read the service manual completely before attempting service on this new series of
power direct vent models
.
How the Safety System Wor
k
s
During normal operation, air for combustion is drawn into the water heater through the inta
k
e
vent pipe from outside your building
.
The air travels into the closed combustion chamber
.
The
air then mixes in a normal manner with supplied gas and is efficiently combusted, producing
Ultra Low NOx emissions
.
In the unli
k
ely event trace amounts of flammable vapors are present in the area surrounding the
water heater, the sealed combustion system prevents the flammable vapors from reaching the
ignition source
.
In addition the flammable vapor sensor will stop the water heater from
operating if a significant amount of flammable vapors are present
.