7
UPV75 Series
Vent Tables
Venting Specifications for:
URG2PV75H*N19, ULG2PV75H*N19
VENT CONNECTOR LENGTHS
FOR 3 in (7.6 cm) DIAMETER VENT PIPE
Terminating
# of
Elbows
(excl. vent
terminals)
Minimum
Straight
Length
ft
(m)
Maximum
Straight
Length
ft
(m)
Installation elevation above
sea level ft
(m)
0-10100
(0-3079)
0-2000
(0-610)
2001-5400
(610-1646)
5401-7800
(1646-2378)
7801-10100
(2378-3079)
Through the Wall
1
2
(0.6)
70
(21.3)
60
(18.3)
30
(9.1)
20
(6.1)
Through the Wall
2
2
(0.6)
65
(19.8)
55
(16.8)
25
(7.6)
15
(4.6)
Through the Wall
3
2
(0.6)
60
(18.2)
50
(15.2)
20
(6.1)
10
(3.0)
Through the Wall
4
2
(0.6)
55
(16.7)
45
(13.7)
15
(4.6)
5
(1.5)
Through the Roof
0
7
(2.1)
75
(22.8)
65
(19.8)
35
(10.7)
25
(7.6)
Through the Roof
1
7
(2.1)
70
(21.3)
60
(18.3)
30
(9.1)
20
(6.1)
Through the Roof
2
7
(2.1)
65
(19.8)
55
(16.8)
25
(7.6)
15
(4.6)
Through the Roof
3
7
(2.1)
60
(18.2)
50
(15.2)
20
(6.1)
10
(3.0)
VENT CONNECTOR LENGTHS
FOR 4 in (10.2 cm) DIAMETER VENT PIPE
Terminating
# of
Elbows
(excl. vent
terminals)
Minimum
Straight
Length
ft
(m)
Maximum
Straight
Length
ft
(m)
Elevation of installation
above sea level ft
(m)
0-10100
(0-3079)
0-5400
(0-1646)
5400-7800
(1646-2378)
7801-10100
(2378-3079)
Through the Wall
1
10
(3.1)
175
(53.3)
160 (
48.8)
105
(32.0)
Through the Wall
2
10
(3.1)
170
(51.8)
155
(47.2)
100
(30.5)
Through the Wall
3
10
(3.1)
165
(50.3)
150
(47.7)
95
(29.0)
Through the Wall
4
10
(3.1)
160
(48.8)
145
(44.2)
90
(27.4)
Through the Wall
5
10
(3.1)
155
(47.2)
140
(42.7)
85
(25.9)
Through the Roof
0
15
(4.6)
180
(54.9)
165
(50.3)
110
(33.5)
Through the Roof
1
15
(4.6)
175
(53.3)
160
(48.8)
105
(32.0)
Through the Roof
2
15
(4.6)
170
(51.8)
155
(47.2)
100
(30.5)
Through the Roof
3
15
(4.6)
165
(50.3)
150
(45.7)
95
(29.0)
Through the Roof
4
15
(4.6)
160
(48.8)
145
(44.2)
90
(27.4)
7