DV Series
24
Honeywell Cover Removal
Step 1.
Rotate the knob of the gas control to the “OFF”
position.
Step 2. Turn off gas supply to the water heater.
Step 3. Disconnect the gas supply line from the gas control.
Step 4. Disconnect the igniter wire.
Step 5. For Honeywell V1, remove the gas control cover
screw using a flat-head screwdriver.
a. For Honeywell V2, remove (4) gas control cover screws using a flat-head screwdriver.
CAUTION
Use caution to not bend or
damage valve body pins
when removing or installing
the gas control cover.
NOTE: The following procedure applies to the Honeywell gas controls ONLY.
Rotate knob counter-clockwise
to the
“OFF”
position
Gas control
cover screw
Service Procedure IV
Gas Control Testing and
Replacement (Honeywell ONLY)
Gas control
screws
24