Bradford White M-I-MS40T6LX Instruction Manual Download Page 5

 

5

General Information continued- 

 

This water heater has been manufactured for operation at altitudes from sea 
level to 2000 feet (610m) (unless otherwise specified on the water heater). 
For use of this appliance at an elevation greater than 2000 feet (610m), contact 
the dealer or manufacturer listed on the rating plate for information on any 
necessary modification.  Uncorrected operation of this appliance may create a 
hazard to life and property. 

 

Make sure to check the rating plate and combination gas control on the water 
heater to be certain that the type of gas being supplied corresponds with the 
marking on the rating plate and combination gas control. 

 

A sacrificial anode is used to extend tank life. The removal of this anode, for 
any reason, will nullify the warranty. In areas where water is unusually active, 
an odor may occur at the hot water faucet due to a reaction between the 
sacrificial anode and the impurities in the water. If this should happen, an 
alternative anode may be purchased from the supplier that installed this water 
heater. This will minimize the odor while protecting the tank. Additionally, the 
water heater should be flushed with appropriate dissolvers to eliminate any 
bacteria. 

INSTALLATION 

Locating the Water Heater 

 

This water heater 

MUST NOT

 be installed in any location where gasoline or 

flammable vapors are likely to be present, unless the installation is such to 
eliminate the probable ignition of gasoline or flammable vapors. 

 

The location of this water heater is of the utmost importance. Before installing 
this water heater, read the Installation section of these instructions.  

DO NOT 

locate the water heater where water lines could be subjected to freezing 
temperatures

.  

Make sure the cold water pipes are not located directly 

above the gas control so that condensate during humid weather does not 
drip on the controls

 

DANGER 

Do not store or use gasoline or other flammable, combustible, or 
corrosive vapors and liquids in the vicinity of this or any other 
appliance.

 

 

WARNING 

Water heaters are heat producing appliances. To avoid damage or 
injury there must be no materials stored against the water heater or 
vent-air intake system and proper care must be taken to avoid 
unnecessary contact (especially by children) with the water heater and 
vent-air intake components. UNDER NO CIRCUMSTANCES MAY 
FLAMMABLE MATERIALS, SUCH AS GASOLINE OR PAINT 
THINNER BE USED OR STORED IN THE VICINITY OF THIS WATER 
HEATER, VENT-AIR INTAKE SYSTEM OR IN ANY LOCATION FROM 
WHICH FUMES COULD REACH THE WATER HEATER OR VENT-
AIR INTAKE SYSTEM. 

Summary of Contents for M-I-MS40T6LX

Page 1: ...nstalled and serviced by a plumbing professional MANUFACTURED HOME MOBILE HOME CLOSED COMBUSTION DIRECT VENTING INSTALLATION AND OPERATING INSTRUCTION MANUAL FOR YOUR SAFETY Do not store or use gasoli...

Page 2: ...installation of this water heater We require that you carefully read this manual as well as the enclosed warranty and refer to it when questions arise If you have any specific questions concerning you...

Page 3: ...nces 7 Drain Pan Installation 9 Combustion Air Supply 10 Venting 11 Water Connections 12 Gas Connections 15 Gas Conversion Instructions 16 GENERAL OPERATION 20 Lighting and Shutdown Instructions 21 Bu...

Page 4: ...ter includes the field installation of the following components roof jack air intake tube and heater tie down materials These components for field installation may have been shipped with this heater a...

Page 5: ...s to eliminate any bacteria INSTALLATION Locating the Water Heater This water heater MUST NOT be installed in any location where gasoline or flammable vapors are likely to be present unless the instal...

Page 6: ...T ANY GAS APPLIANCE IF YOU ARE NOT CERTAIN OF THE FOLLOWING Liquefied petroleum gases propane gas and natural gas have an odorant added by the gas supplier that aids in detection of the gas Most peopl...

Page 7: ...ith sealant in a smooth and easily cleanable way or b Installed with an optional leg kit that includes legs and or extensions that provide a minimum clearance of 6 beneath the water heater Note For Ca...

Page 8: ...8 Installation continued Figure 1 IMPORTANT The flow of combustion and ventilating air must not be obstructed Minimum Clearances From Combustible Materials A 0 0cm B 0 0cm C 3 7 62cm D 78 1 98mm VENT...

Page 9: ...final installation 4 Align drain pan hole with hole cut in floor and underside sheathing for air intake 5 Apply 4 diameter circle of silicone around bottom of air intake plate and screws used to secu...

Page 10: ...the combustion chamber burners and flue tubes with possible damage to the heater AIR INTAKE INSTALLATION 3 7 6cm diameter telescoping air intake and leg enclosure are required to supply fresh air to t...

Page 11: ...ened to the top of the water heater and to the adjacent walls with the screws provided See Figure 5 Venting Make certain the flue baffle is in place and centered in the flue tube Cut a 7 1 4 inch 18 5...

Page 12: ...house Install a shut off valve in the cold water supply line CAUTION If sweat fittings are to be used DO NOT apply heat to the nipples on top of the water heater Sweat the tubing to the adapter befor...

Page 13: ...Relief Valves The combination temperature and pressure relief valve shall be marked with a maximum set pressure not to exceed the maximum working pressure of the water heater The combination temperat...

Page 14: ...for a long period of time generally two weeks or more Hydrogen gas is extremely flammable To prevent the possibility of injury under these conditions we recommend the hot water faucet to be open for...

Page 15: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Page 16: ...or by removing cap from gas regulator Depress and rotate knob clockwise to NAT setting using a screwdriver Replace cap Figure 6 3 Change the pilot regulator by removing pilot regulator cap Depress and...

Page 17: ...provided with the water heater 2 Change the main gas regulator to LP as noted in step 2 of the instructions 3 Change the pilot regulator to LP as noted in step 3 of the instructions 4 Replace equipped...

Page 18: ...igure 7 only 1 Follow the instructions above except remove cap from gas regulator and depress and rotate plunger counterclockwise 2 Remove main burner orifice and pilot assembly and replace with RED c...

Page 19: ...this installation and operation instruction manual 10 Remove equipped for card from cloth bag and attach to gas piping as close to gas control as possible Remove and discard tag attached to water inl...

Page 20: ...Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockwise The drain valve has threads on...

Page 21: ...21 Lighting and Shutdown Instructions...

Page 22: ...al until the minimum acceptable temperature is achieved See Figure 9 above for approximate temperature settings Figure 10 The thermostat dial is set to its lowest temperature setting when shipped from...

Page 23: ...ot be greater than the mark on the thermostat dial approximately 120 F 48 9 C as pictured above Rotate the thermostat dial clockwise to decrease the temperature setting Rotate the thermostat dial coun...

Page 24: ...tall an ASSE approved mixing valve in the water system This valve will reduce point of discharge temperature by mixing cold and hot water in branch water lines A licensed plumbing professional or loca...

Page 25: ...t least once a year check the combination temperature and pressure relief valve to insure that the valve has not become encrusted with lime Lift the lever at the lever at the top of the valve several...

Page 26: ...TION OF THE LENGTH OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED Complete the following information and retain for future reference Model No Serial No Service Phone Days Nights Address Supplie...

Page 27: ...27 TYPICAL INSTALLATION...

Page 28: ...ket Top 13 Thermostat w ECO Convertible Nat or L P Gas 3 Fiberglass Insulation 14 Pilot Assembly 4 Glass Lined Tank 15 Gas Feed Line Burner 5 Tank Skirt Assembly 16 Main Burner Orifice 6 Jacket Base A...

Reviews: