Water Connections continued- 
 

 

WARNING 

For protection against excessive temperatures and pressure, install 
temperature and pressure protective equipment required by local codes, 
but not less than a combination temperature and pressure relief valve 
certified by a nationally recognized testing laboratory that maintains 
periodic inspection of production of listed equipment or materials, as 
meeting the Requirements for 

Relief Valves and Automatic Gas Shutoff 

Devices for Hot Water Supply Systems, ANSI Z21.22

, and the Standard 

CAN1-4.4 Temperature, Pressure, Temperature and Pressure Relief 
Valves and Vacuum Relief Valves

.  The combination temperature and 

pressure relief valve shall be marked with a maximum set pressure, not to 
exceed the maximum working pressure of the water heater.  The 
combination temperature and pressure relief valve shall also have an 
hourly rated temperature steam BTU discharge capacity not less than the 
hourly input rating of the water heater. 
 
Install the combination temperature and pressure relief valve into the 
opening provided and marked for this purpose on the water heater 
 
Note:  Some models may already be equipped or supplied with a 
combination temperature and pressure relief valve.  Verify that the 
combination temperature and pressure relief valve complies with local 
codes.  If the combination temperature and pressure relief valve does not 
comply with local codes, replace it with one that does.  Follow the 
installation instructions above on this page. 
 
Install a discharge line so that water discharged from the combination 
temperature and pressure relief valve will exit within six (6) inches (15.3 
cm) above, or any distance below the structural floor and cannot contact 
any live electrical part.  The discharge line is to be installed to allow for 
complete drainage of both the temperature and pressure relief valve and 
the discharge line.  The discharge opening must not be subjected to 
blockage or freezing.  

DO NOT

 thread, plug or cap the discharge line.  It is 

recommended that a minimum of four (4) inches (10.2 cm) be provided on 
the side of the water heater for servicing and maintenance of the 
combination temperature and pressure relief valve. 
 
Do not place a valve between the combination temperature and pressure 
relief valve and the tank.

 

 

8

Water Connections continued- 

 

 

 

 

WARNING 

Hydrogen gas can be produced in a hot water system served by this 
water heater that has not been used for a long period of time 
(generally two weeks or more).  Hydrogen gas is extremely 
flammable.  To reduce the risk of injury under these conditions, it is 
recommended that the hot water faucet be opened for several 
minutes at the kitchen sink before using any electrical appliance 
connected to the hot water system.  If hydrogen is present, there will 
probably be an unusual sound such as air escaping through the pipe 
as the water begins to flow.  There should be no smoking or open 
flame near the faucet at the time it is open.

 

CAUTION

 

INCREASING THE THERMOSTAT SETTING ABOVE THE PRESET 
TEMPERATURE MAY CAUSE SEVERE BURNS AND CONSUME 
EXCESSIVE ENERGY.  HOTTER WATER INCREASES THE RISK OF 
SCALD INJURY.

 

Summary of Contents for M-2-120R6DS-5500W

Page 1: ...TABLE OF CONTENTS General Information 3 Installation 4 Locating The Water Heater 4 Water Connections 6 Electrical Connections 13 General Operation 14 Thermostat Adjustment 15 Maintenance 16 Notes 19...

Page 2: ...rrosive vapors and liquids in the vicinity of this or any other appliance 4 General Information continued A sacrificial anode is used to extend tank life Removal of this anode for any reason will null...

Page 3: ...ter heater must be braced anchored or strapped to avoid falling or moving during an earthquake See instructions for correct installation procedures Instructions may be obtained from DSA Headquarters O...

Page 4: ...n instructions above on this page Install a discharge line so that water discharged from the combination temperature and pressure relief valve will exit within six 6 inches 15 3 cm above or any distan...

Page 5: ...120 F 49 C More than 5 minutes 125 F 52 C 1 to 2 minutes 130 F 54 C About 30 seconds 135 F 57 C About 10 seconds 140 F 60 C Less than 5 seconds 145 F 63 C Less than 3 seconds 150 F 66 C About 1 secon...

Page 6: ...ctions apply appropriate amount of thread sealant to the provided nipples and install nipples in desired top location Apply appropriate amount of thread sealant to the pipe plugs and install pipe plug...

Page 7: ...ter is automatic The thermostats are preset to the HOT setting to provide a water temperature of approximately 120 F 49 C to reduce the risk of scald injury Care must be taken whenever using hot water...

Page 8: ...r is off Shut off the electric power and water supply drain the water heater completely to prevent freezing whenever the building is left unoccupied during the cold weather months In order to insure e...

Page 9: ...any released water does not result in bodily injury or property damage WARNING THIS WATER MAY BE HOT CAUTION FOR YOUR SAFETY DO NOT ATTEMPT TO REPAIR THERMOSTAT S HEATING ELEMENTS OR ELECTRICAL WIRING...

Page 10: ...19 NOTES 20 NOTES...

Reviews: