Light Duty Utility Energy Saver Models
Meet or exceed ASHRAE 90.1b (current standard) C.E.C. Listed
Model
Number
Approx.
Shipping
Weight
lbs.
E
Floor to
Cold Water
Conn.
in.
B
Jacket
Dia.
in.
A
Floor to
Heater
Top
in.
U.S.
Gal.
Capacity
Recovery
100°F Rise
LD-6U3-1†
LD-10U3-1†
LD-12UT3-1†
LD-15U3-1†
LD-20U3-1
LD-30U3-1
6
10
12
15
19
30
Imp.
Gal.
5
8
10
13
16
25
U.S.*
GPH
6
6
6
6
6
6
Imp.*
GPH
5
5
5
5
5
5
33
48
48
55
59
82
16
1
/
2
17
1
/
2
27
3
/
4
20
1
/
4
24
3
/
4
30
C
Floor to
Hot Water
Conn.
in.
10
1
/
8
15
21
1
/
8
17
3
/
4
18
1
/
4
23
1
/
2
14
16
14
18
18
22
3
1
/
8
5
11
/
16
3
6
1
/
8
3
4
1
/
2
10
1
/
8
14
21
1
/
8
16
3
/
4
18
1
/
4
23
1
/
2
D
Floor to
T&P
Conn.
in.
Model
Number
Approx.
Shipping
Weight
kg.
E
Floor to
Cold Water
Conn.
mm.
B
Jacket
Dia.
mm.
A
Floor to
Heater
Top
mm.
Liters
Capacity
Recovery
56°C Rise
LD-6U3-1†
LD-10U3-1†
LD-12UT3-1†
LD-15U3-1†
LD-20U3-1
LD-30U3-1
23
38
45
57
72
114
Liters/*
Hour
23
26
23
26
23
23
15
22
22
25
27
37
444
246
730
257
464
787
419
444
705
514
629
762
C
Floor to
Hot Water
Conn.
mm.
257
381
537
451
464
597
356
404
356
457
457
557
79
144
76
155
76
114
F
Floor to
Anode
Rod
in.
16
1
/
2
9
11
/
16
27
3
/
4
10
1
/
8
10
1
/
4
30
F
Floor to
Anode
Rod
mm.
G
Floor to
Electrical
Access
in.
16
1
/
2
12
27
3
/
4
12
11
/
16
24
3
/
4
30
G
Floor to
Electrical
Access
mm.
419
305
705
309
628
762
257
355
537
425
464
59
D
Floor to
T&P
Conn.
mm.
Commercial Electric Water Heater
General
All models UL and CUL listed. These heaters are wired Single Phase, 120V with one 1500W element,
unless otherwise specified.
All water and electrical connections are 3/4" (19mm)NPT.
All models certified at 300 psi test pressure (2068 kPa) and 150 psi working pressure (1034 kPa).
Applicable models CSA verified for energy performance in accordance with C191.1-M90.
Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement.
Recovery
GPH Temperature Rise °F
Wattage
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
60
10
14
17
21
24
28
31
34
38
41
80
8
10
13
15
18
21
23
26
29
31
90
7
9
11
14
16
18
21
23
25
28
100
6
8
10
12
14
16
19
21
23
25
120
5
7
9
10
12
14
15
17
19
21
B
C D
F
E
G
A
B
F
F
C
E
D
G
A
4"
ALTERNATE
COLD INLET
(PLUGGED)
6, 12 GAL.
ONLY
PLUG TYPE
ANODE
6, 12, & 30
GAL. ONLY
ALTERNATE HOT
OUTLET (PLUGGED)
6, 12 GAL. ONLY
8"
6, 12, 20 & 30 Gallon Models
Printed in U.S.A.
412-B-0408-A
©2008, Bradford White Corporation. All rights reserved.
Ambler, PA
For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative.
Sales
800-523-2931
●
Fax
215-641-1670
/ Technical Support
800-334-3393
●
Fax
269-795-1089
●
Warranty
800-531-2111
●
Fax
269-795-1089
International:
Telephone
215-641-9400
●
Telefax
215-641-9750 / www.bradfordwhite.com
Sales / Technical Support
866-690-0961
/
905-238-0100
●
Fax
905-238-0105
/
www.bradfordwhite.com
Voltage
Wattage
Limitations
1500W
2000W
2500W
3000W
3500W
4000W
4500W
5000W
5500W
6000W
yes
yes
yes
yes
no
no
no
no
no
no
120V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
208V
yes
yes
yes
yes
yes
yes
yes
yes
yes
yes
240V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
277V
yes
yes
yes
yes
no
yes
yes
yes
no
yes
480V
Specify wattage and voltage when ordering.
Use chart to right for maximum wattages at certain voltages.
†Maximum wattage at any voltage is 3000W.
For 5 year models, change suffix "3" to "5".
Single element only.
*Based on 1500W operation.
NSF Construction not available.
10 & 15 Gallon Models