background image

Installation 

 

Wire connection 
Note
:  

Power to the unit is provided from the listed control unit or from a 

separately UL listed 12V DC power-limited, access control power source. 

DO NOT supply power during installation. 

 

Wiring methods shall be in accordance with the Electrical wiring regulation 

in your country / region. 

 

Check your circuit diagram for the colour coding of the circuit wiring. The 

reader can be damaged beyond repair if the wiring is connected incorrectly. 

This will void the warranty.

 

 

1.

 

Connect the 0V wire to the power 0V line; 

Note: The 0V line of all power supplies must be connected to a common 0V reference 

point. 

2.

 

Connect the Wiegand data wires; 

3.

 

Connect the Buzzer and LED wires; 

4.

 

Connect 12V DC wire; 

5.

 

Place reader on the mounting box (Make sure the wires are not 

crushed. This will void the warranty if damage occurs) 

6.

 

Insert and hand tighten the screws; 

7.

 

Check that the reader is level before tightening the screws; 

Note: Excessive tightening of screws may deform the casing, resulting in a damaged 

unit. This will void the warranty. 

8.

 

Turn on the 12V DC power to power up reader.  

9.

 

Allow 5 – 10 seconds for reader to finish initialization (depends on the 

application). Make sure reader is functioning correctly according to 

the application specification. 

 

External Use 

 

Make sure the wire bundle to the reader has an IP rating of at least IP65 

 
Handling 

 

Handle the reader with care. DO NOT damage or drop unit before 
installation. This will void the warranty. 

 

If the case is damaged, the reader may not be to the specified IP rating. 
Replace the reader if the case is damaged. 

 
Maintenance 

 

Once installed the reader requires no maintenance. 

 

Troubleshooting 

Problem 

Troubleshooting steps 

Power on reader – reader does 

not start up 

1.

 

Check connections 

2.

 

Check the voltage at the reader 

3.

 

Check the current capability of the power 

supply 

 

Power on reader – reader keeps 

beeping 

1.

 

Check buzzer line 

2.

 

Check the voltage at the reader 

3.

 

Check the current capability of the power 

supply  

 

Power on reader – LED stays 

green 

1.

 

Check LED line 

 

Present a card to reader – a beep 

is heard but reader does not 

output any data 

1.

 

Check whether the card has data encoded 

2.

 

Check the wiegand connection to controller 

3.

 

Check the voltage level on wiegand data lines 

 

Present a card to reader – no 

response from reader 

1.

 

Try a known working card 

2.

 

Check if the reader requires to be configured 

with a  configuration card 

 

If the problem still persists, please contact your distributor for technical support. 
 

Reader Dimensions

 

 

BT825 (3mm flush face). Compatible with AU/US single gang box 

 

 

BT835 (UK Size Plate). Compatible with UK single gang box 

 

 

BT835 (AU Size Plate). Compatible with AU/US single gang box 

 
 

 

BT835 AU/D Model (6mm Perplex plate), Custom mounting holes 

 

 

BT835 UN Model (6mm Perplex plate), Custom mounting holes 

Reviews: