Installation
Wire connection
Note:
Power to the unit is provided from the listed control unit or from a
separately UL listed 12V DC power-limited, access control power source.
DO NOT supply power during installation.
Wiring methods shall be in accordance with the Electrical wiring regulation
in your country / region.
Check your circuit diagram for the colour coding of the circuit wiring. The
reader can be damaged beyond repair if the wiring is connected incorrectly.
This will void the warranty.
1.
Connect the 0V wire to the power 0V line;
Note: The 0V line of all power supplies must be connected to a common 0V reference
point.
2.
Connect the Wiegand data wires;
3.
Connect the Buzzer and LED wires;
4.
Connect 12V DC wire;
5.
Place reader on the mounting box (Make sure the wires are not
crushed. This will void the warranty if damage occurs)
6.
Insert and hand tighten the screws;
7.
Check that the reader is level before tightening the screws;
Note: Excessive tightening of screws may deform the casing, resulting in a damaged
unit. This will void the warranty.
8.
Turn on the 12V DC power to power up reader.
9.
Allow 5 – 10 seconds for reader to finish initialization (depends on the
application). Make sure reader is functioning correctly according to
the application specification.
External Use
•
Make sure the wire bundle to the reader has an IP rating of at least IP65
Handling
•
Handle the reader with care. DO NOT damage or drop unit before
installation. This will void the warranty.
•
If the case is damaged, the reader may not be to the specified IP rating.
Replace the reader if the case is damaged.
Maintenance
•
Once installed the reader requires no maintenance.
Troubleshooting
Problem
Troubleshooting steps
Power on reader – reader does
not start up
1.
Check connections
2.
Check the voltage at the reader
3.
Check the current capability of the power
supply
Power on reader – reader keeps
beeping
1.
Check buzzer line
2.
Check the voltage at the reader
3.
Check the current capability of the power
supply
Power on reader – LED stays
green
1.
Check LED line
Present a card to reader – a beep
is heard but reader does not
output any data
1.
Check whether the card has data encoded
2.
Check the wiegand connection to controller
3.
Check the voltage level on wiegand data lines
Present a card to reader – no
response from reader
1.
Try a known working card
2.
Check if the reader requires to be configured
with a configuration card
If the problem still persists, please contact your distributor for technical support.
Reader Dimensions
BT825 (3mm flush face). Compatible with AU/US single gang box
BT835 (UK Size Plate). Compatible with UK single gang box
BT835 (AU Size Plate). Compatible with AU/US single gang box
BT835 AU/D Model (6mm Perplex plate), Custom mounting holes
BT835 UN Model (6mm Perplex plate), Custom mounting holes