Drilling template
•
20mm (0.79”) diameter hole for wire entry
•
2 x 4 mm (0.16”) diameter holes for mounting screws
•
Inner reader dimension is 88mm x 88 mm (3.47" x 3.47")
•
Assemble reader outer dimension is 90mm x 90mm (3.54” x 3.54”)
•
Reader corner radius is 4mm (0.16”)
Specifications
Output protocols
Wiegand 26-199bit, RS485 or custom configuration (Model
dependentt)
Power requirement
7-18V DC
Current
consumption
31mA (Idle)
158mA (Peak)
Read range
20-40mm (0.8”-1.6”) at 12V DC depends on the type of card
used
Relay Rating
80mA
Operating
temperature
-25’C to +65’C (-13’F to 149’F)
Relative humidity
90% max, operating non-condensing
Reader dimensions
90mm(L) x 90mm(W) x 27mm(D) (3.54”x3.54”x1.06”)
Status LED
Green & Red
Audible tone
Internal and external buzzer control
Keypad
3 x 4 Keypad illuminated
Colour finish
Charcoal
IP rating
IP65
Information obtained in this document is subject to change without notice.
For further technical information, visit our website at www.bqtsolutions.com or email
Alternatively contact us at one of our global locations
AUSTRALIA & PACIFIC
BQT Solutions (Australia) Pty Limited
Unit 29, 1 Talavera Road
North Ryde, NSW 2113, Australia
Phone: +61 (0)2 8817 2800
Fax: +61 (0)2 8817 2811
Email: [email protected]
EUROPE AND MIDDLE EAST
BQT Solutions (UK) Limited
Regus, Castle Court, 41 London Road
Reigate, RH2 9RJ
United Kingdom
Phone: +44 (0)17 3773 5071
Fax: +44 (0)17 3773 5072
Email: [email protected]
GREATER ASIA
BQT Solutions Singapore Office
61 Tras Stras Street
#02-01
Singapore 079000
Phone: +65 6220 7970
Fax: +65 6220 7656
Email: [email protected]
Copyright © 2015 BQT Solutions Limited. BQT Solutions and the BQT solutions logo are registered trademarks of BQT Solutions (Australia) Pty Ltd.
Wiring diagram
Note:
•
A shielded cable is recommended to be used. The shield is connected to controller 0V reference
•
Maximum wiegand data cable length: 150 meters (500 feet)
•
Buzzer and LED are low activated.
•
RS485 and Relay are only for optional use
•
Terminate or insulate all un-used wires
Regulatory Information
C-Tick: This device is C-Tick complied.
CE: This device has passed all relevant tests and obtained CE approval.
FCC: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) this device
may not cause interference and 2) this device must accept any interference, including interference that may cause
undesired operation of the device.
Warning: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part
15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressively approved by BQT Solutions could void the user’s authority to operate this
equipment.
7
Series
INSTALLATION GUIDE
Version3.1