Installation 
The BT853 should be located approximately 165 cm above the floor on the 
wall surface. Care should be taken to position the unit so as to minimize 
reflections on the display from external light sources. Fluorescent lights 
directly overhead and down lights at the unit should be avoided. 
 
To mount the BT853, the bracket should be secured to the wall or gang box 
using the corresponding screw holes, before attaching the unit itself. (See 
Mounting Hole Dimensions). 
 
After the bracket is installed, mount BT853 unit onto bracket (follow the 
diagram below) and secure the unit with two M4 screws at the bottom of 
unit.

  

 

Note: 

Make sure that you don't drill through the cable.

 

 

Wire connection 
Note
:  

Power to the unit is provided from the listed control unit or from a 

separately UL listed 12V DC power-limited, access control power source. 

DO NOT supply power during installation. 

 

Wiring methods shall be in accordance with the Electrical wiring regulation 

in your country / region. 

 

Check your circuit diagram for the colour coding of the circuit wiring. The 

device can be damaged beyond repair if the wiring is connected incorrectly. 

This will void the warranty.

 

 

1.

 

Connect the 0V wire to the power 0V line; 

Note

: The 0V line of all power supplies must be connected to a common 0V reference 

point. 

 

2.

 

Connect the Wiegand data wires; 

 

3.

 

Connect the Buzzer and LED wires; 

 

4.

 

Connect 12V DC wire; 

 

5.

 

Place unit on the wall (Make sure the wires are not crushed. This will 

void the warranty if damage occurs) 

 

6.

 

Insert and hand tighten the screws; 

 

7.

 

Check that the unit is level before tightening the screws; 

Note

: Excessive tightening of screws may deform the casing, resulting in a damaged 

unit. This will void the warranty. 

 

8.

 

Turn on the 12V DC power to power up the device.  

 

9.

 

Allow 5 – 10 seconds for the device to finish initialization (depends on 

the application). Make sure the unit is functioning correctly according 

to the application specification. 

 
 
 
 
 
 
 
 

External Use 

 

Make sure the wire bundle to the device has an IP rating of at least IP65 

 
Handling 

 

Handle the device with care. DO NOT damage or drop unit before 
installation. This will void the warranty. 

 

If the case is damaged, the unit may not be to the specified IP rating. 
Replace the unit if the case is damaged. 

 
Maintenance 

 

Once installed the device requires no maintenance. 

 

Troubleshooting 

Problem 

Troubleshooting steps 

Power on reader – reader does 

not start up 

1.

 

Check connections 

2.

 

Check the voltage at the reader 

3.

 

Check the current capability of the power 

supply 

 

Power on reader – reader keeps 

beeping 

1.

 

Check buzzer line 

2.

 

Check the voltage at the reader 

3.

 

Check the current capability of the power 

supply  

 

Power on reader – LED stays 

green 

1.

 

Check LED line 

 

Present a card to reader – a beep 

is heard but reader does not 

output any data 

1.

 

Check whether the card has data encoded 

2.

 

Check the wiegand connection to controller 

3.

 

Check the voltage level on wiegand data lines 

 

Present a card to reader – no 

response from reader 

1.

 

Try a known working card 

2.

 

Check if the reader requires to be configured 

with a  configuration card 

 

 
If the problem still persists, please contact your distributor for technical support. 
 
 

Warranty 
Unless specified otherwise, the Company warrants to the Customer that’ 
BQT Solutions Branded Products’ (excluding third party products and 
software) are covered by a return to base warranty on defects in materials 
and workmanship affecting normal use for a period of the Warranty offered 
under the Standard Terms and Conditions of Sale from BQT invoice date 
(‘Standard Warranty’) 
 
This standard warranty does not cover damage, fault, failure or malfunction 
due to external causes including; accident, misuse, problems with electrical 
power, servicing not authorised by the Company,  usage and/or storage 
and/or installation not in accordance with Product instructions, failure to 
perform required preventative maintenance, normal wear and tear, act of 
God, fire, flood, war, any violent or similar occurrence; any attempt by any 
person other than Company personnel or any person authorised by the 
Company  to repair or support the Products and problems caused by use of 
parts and components not supplied by the Company.  The standard warranty 
does not cover any items that are in one or more of the following categories: 
software; external devices; accessories or parts added to the product after 
the product has been shipped from BQT Solutions.  
 
During the warranty, period beginning on the invoice date, the Company will 
repair or replace faulty products (at its absolute discretion) returned to its’ 
factory. The Customer must prepay shipping and transportation costs and 
insure the shipment or accept the risk of loss or damage during such 
transportation. 
 
The Customer shall be solely responsible for determining suitability for use 
and the Company will, in no event, be liable in this respect. This standard 
warranty is given in place of all warranties, conditions, terms, undertakings 
and obligations implied by statute, common law, trade usage, and course of 
dealing or otherwise including warranties or conditions of merchantability, 
fitness for purpose, satisfactory quality and / or compliance with description, 
all of which are hereby excluded to the fullest extent permitted by law. 

Reviews: