background image

 

 

 

NO VIDEO SIGNAL 

 

1.  CHECK BRIGHTNESS/CONTRAST SETTING ON MONITOR (THUMBWHEEL) NOT AT MINIMUM 

(TURN CLOCKWISE FOR ON). 

2.  CHECK 5 & 6 = 17.5VDC ON CAMERA UNIT. 

3.  CHECK 14 ON CAMERA UNIT LINKED TO 14 ON VA/100 & CHECK FOR 17.5VDC ACROSS 6 (+VE) 

& 14(-VE) ON CAMERA UNIT AFTER CALL/PREVIEW. 

4.  MEASURE ACROSS COAXIAL CABLE AT CAMERA = 75 ohms (EOL RESISTOR). 

5.  CHECK O/P OF CAMERA DIRECTLY WITH BATTERY MONITOR AFTER LINKING 5 & 14 ON 

CAMERA UNIT. 

 

 

NO DOOR RELEASE 

 

1.  CHECK DOOR RELEASE TIMER ON VA/100 NOT AT MINIMUM (ANTI-CLOCKWISE IS MINIMUM). 

2.  CHECK 240VAC INPUT TO VA/100. CHECK FUSE F4 IN VA/100. 

3.  PRESS DOOR RELEASE (KEY) BUTTON, CHECK B5 & B9 = 4VDC WHILST KEY BUTTON 

PRESSED. IF > 4VDC INCREASE CABLE CROSS SECTION TO MONITOR (5,6 & 9). 

4.  AFTER PRESSING KEY BUTTON CHECK C1 & C13 = 12 TO 18VAC FOR DURATION OF TIMER. 

5.  CHECK CABLE CROSS SECTION/RATING OF RELEASE (12VAC & 1A FAIL SECURE). 

 

 

FEEDBACK 

 

RECOMMEND LOWER MICROPHONE ON TARGA (HAV/200) ENSURE VOLUME POTENTIOMETERS IN 

PANEL ARE CORRECTLY BALANCED (SMALL ADJUSTMENTS USUALLY REQUIRED. 

 

 

 

 

 

PRIOR TO CONTACTING TECHNICAL SUPPORT IT IS GOOD ENGINEERING PRACTICE TO CONNECT MONITOR & PANEL ON 

SHORT LEADS DIRECTLY INTO VA100 UNIT.THIS WILL INDICATE CABLE PROBLEMS/WRONG CONNECTIONS THAT 

CONSTITUTE THE MAJORITY OF CALLS TO OUR TECHNICAL SUPPORT DEPARTMENT. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(c:kr/winword/document/instruc)

 