background image

CENTRALITA DE CONTROL
GVV/200

Permite el funcionamiento de los
módulos manos libres NC/220,
XC/220 y NC/221, XC/221 en instala-
ciones de audiointercomunicacion y de
videointercomunicacion de la serie 200.
Su tarea principal consiste en deter-
minar la dirección de la comunica-
ción y en reducir automáticamente
el volumen del canal opuesto.

GVV/200 MAIN CONTROL UNIT

Enables the twin-channel receivers
NC/220, XC/220 and NC/221,
XC/221 to be operated in series-200
audio- and video entry installations.
Its main function consists in determi-
ning the direction of communication
and automatically reducing the volu-
me of the opposite channel.
To permit the balancing circuit to
work properly, the volume controls in
the entry panels must be set, the
MR/100 remote microphone instal-
led in TM-series entry panels, and
the microphone in Targha-series
entry panels moved to the remote
position.

Adjustment of the audio volume
controls.
Targha-series entry panels:

both

half way.

TM-series entry panels:

the one

towards the receivers almost at the
minimum setting, and the one
towards the entry panel at the desi-
red volume.

The switchboard comes with two
jumpers, 

SW1

and 

SW2

, which

should be positioned depending on
the type of user extension and
power supplier used in the installa-
tion (fig. 1):

SW1 OFF - SW2 OFF

in installations

with NC/220, XC/220 and A/200;

SW1 ON - SW2 OFF

in installations

with NC/221, XC/221 and VA/200;

SW1 ON - SW2 ON

in installations

with NC/221, XC/221 and A/200
with GS/200.

Function of each terminal

(fig. 1)

IN terminal board
11

audio from entry panel

12

audio to entry panel

OUT terminal board
5

power supply

21

+

11

audio to receiver

12

audio from receiver

M

mute (1)

(1) In the event loud noises in the
area around the entry panel make
automatic switching difficult, the
audio channel from the entry panel

1

SW1

11

12

OUT

11

21
5

IN

12

M

ON

OFF

SW2

1

GVV/200 US

E

INSTRUCCIONES
PARA LA INSTALACION

02.2009/2405-9112

1

2

3

can be disabled by connecting the
terminal 

M

(mute) to earth using the

auxiliary button of the twin-channel
receiver.

Technical features

• Supply voltage: 12 VDC.
• Current demand: max. 50 mA. 
• Working temperature range: from

0 °C to +35 °C.

• Dimensions: 60x44x16mm (fig. 2).
The unit can be installed on a DIN
guide (EN 50022) (fig. 3).

DISPOSAL

Do not litter the environment with
packing material: make sure it is dis-
posed of according to the regula-
tions in force in the country where
the product is used.
When the equipment reaches the
end of its life cycle, take measures to
ensure it is not discarded in the envi-
ronment.
The equipment must be disposed of
in compliance with the regulations in
force, recycling its component parts
wherever possible.
Components that qualify as recy-
clable waste feature the relevant
symbol and the material’s abbrevia-
tion.

60 mm

4

4

m

m

16 mm

2

BPT S.p.A.

Via Cornia, 1

33079 Sesto al Reghena-PN-Italy

[email protected]  –  www.bpt.it

NOTE:

This equipment has been tested and found to com-

ply with the limits for a Class B digital device, pursuant to Part
15 of the FCC Rules. These limits are designed to provide

reasonable protection against harmful interference in a residential instal-
lation.
This equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is
no guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
- Reorient or relocate the receiving antenna. 
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.

EN INSTALLATION

INSTRUCTIONS

LEVITON

LEVITON S de RL de CV
LAGO TANA 43 Col HUICHAPAN CP
11290
MEXICO DF Tel 5082 1040

LEA Y CONSERVE ESTE

INSTRUCTIVO

 

Summary of Contents for GVV/200 US

Page 1: ...bled by connecting the terminal M mute to earth using the auxiliary button of the twin channel receiver Technical features Supply voltage 12 VDC Current demand max 50 mA Working temperature range from 0 C to 35 C Dimensions 60x44x16mm fig 2 The unit can be installed on a DIN guide EN 50022 fig 3 DISPOSAL Do not litter the environment with packing material make sure it is dis posed of according to ...

Page 2: ...s límites establecidos para un dispositivo digital de Clase B de acuerdo con el Apartado 15 de las Normas FCC Estos límites han sido diseñados para ofrecer una protección razonable contra interferencias perjudiciales en una instalación residencial Este equipo genera utiliza y puede emitir energía de radiofrecuencia y si no se instala y utiliza conforme a las instrucciones puede crear interferencia...

Page 3: ... C 0 5 mm2 A 1 mm2 B 0 5 mm2 150 m 100 m CP Personal door bell button Pulsador de llamada desde el rellano AE Auxiliary door lock release button Pulsador auxiliar abrepuerta WIRE CROSS SECTION SECCION DE LOS CONDUCTORES ...

Page 4: ...00 21 11 12 M 5 OUT IN 11 12 B B B B B NC 220 B SW1 4 B 1 2 3 4 5 7 8 9 5 7 8 9 SW2 XC 220 5 7 8 9 2 CP B L N 4 SE 7503 2 UL SINGLE OR MULTI FLAT AUDIO ENTRY INSTALLATION WITH NOVA EXEDRA HANDS FREE RECEIVERS AND TARGHA ENTRY PANEL EQUIPO DE AUDIOINTERCOMUNI CACION MONO O MULTIFAMILIAR CON DERIVADOS INTERNOS MANOS LIBRES NOVA EXEDRA Y PLACA EXTERNA TARGHA ...

Page 5: ...9 E 20 XC 221 2 CP 5 7 8 9 20 B B B B B C B B YC 201 C 5 7 8 9 20 E XC 200 SC 200 SC 200 C 5 7 8 9 20 E 5 7 8 9 CP SC 200 C 200 SC 200 C 5 7 8 9 20 E 5 7 8 9 CP L N SE 7504 2 UL MULTI FLAT MIXED AUDIO ENTRY INSTALLATION WITH HANDSETS AND NOVA EXEDRA HANDS FREE RECEIVERS AND TARGHA ENTRY PANEL EQUIPO DE AUDIOINTERCOMUNI CACION MULTIFAMILIAR MIXTO CON DERIVADOS INTERNOS CON AURICULAR Y MANOS LIBRES ...

Page 6: ... 8A 22 11 12 23 14 13 16 3 4 5 6 7 8 9 E 5 7 8 9 E 20 SW1 SW2 XVC 200 XKP 200 XC 221 XKP 85 CP 3 4 5 6 7 8 9 20 E XC 221 CNH C L N 75 75 SE 8041 2 UL SINGLE HOUSE VIDEO ENTRY INSTALLATION WITH NOVA EXE DRA HANDS FREE MONITOR AND TARGHA ENTRY PANEL EQUIPO DE VIDEOINTERCOMUNI CACION MONOFAMILIAR CON MONITOR MANOS LIBRES NOVA EXEDRA Y PLACA EXTERNA TAR GHA ...

Page 7: ... 9 20 E CNH 75 CP CP 5 7 8 9 E 20 75 CP 2 YKP 200 YV M1 M2 7A 3 4 5 6 7 8 9 10 11 12 18 19 20 75 CP YVM 200 3 4 5 6 7 8 9 10 11 18 20 75 XV 200 XKP 200 XC 200 XKP 85 CP 3 4 5 6 7 8 9 20 E C XC 200 CN 2 VM 200 VKP 203 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 CP 75 L N 7 SE 8042 3 UL MULTI FLAT MIXED VIDEO ENTRY INSTALLATION WITH MONITORS WITH HANDSET NOVA EXEDRA HANDS FREE MONITORS AND TARGHA...

Page 8: ... MVTC 100 MC MR 100 AE 12V 1 2 3 4 n n MVA 100 01 MR 100 4 2 1 4 5 6 14 5 6 17 19 5 6 8 11 12 14 SW1 SW3 SW2 C 1 2 3 4 SW2 L N 5 Fig 4 Connection diagram bet ween A 200R power supplier GVV 200 main control unit and TM Fig 4 Esquema de conexión entre el alimentador A 200R centralita de control GVV 200 y la placa exterior TM 4 3 8A 9 8 5 B C A 200N B 5 21 8 8A 11 12 23 5 8 9 16 NO C NC AE 12V A B B ...

Reviews: