background image

Flush Mount 

Mounting of ULTRA50 EXIT Sign to Surface 

 

1.

 

Place the EXIT Sign in position and mark the screw hole locations. 

2.

 

If wall anchors will be required, install them at this time (Supplied). 

3.

 

Attach the ULTRA50 EXIT Sign to the wall by using the two supplied #8 Phillips head screws.  Be careful not to over 

tighten the screws. 

4.

 

If a directional arrows are to be used, apply them to the EXIT Sign at this time.  

a.

 

Alignment dots are provided on the face of the sign to ensure proper positioning of the arrows. 

i.

 

For Exit paths straight ahead, no arrows are needed. 

ii.

 

For Exit paths to the left, apply the arrow on the left side of the EXIT Sign.  

iii.

 

For Exit paths to the right, apply the arrow on the right side of the Exit Sign.     

iv.

 

If Exit paths are located to the left and right, apply both arrows to the EXIT Sign. 

 

Flag or Ceiling or T-Bar Mount 

Installation Instructions for the ULTRA50 EXIT Sign 

 

 

1.

 

If directional arrows are to be used, apply them to the EXIT Sign at this time.  

a.

 

Alignment dots are provided on the face of the sign to ensure proper positioning of the arrows. 

i.

 

For Exit paths straight ahead, no arrows are needed. 

ii.

 

For Exit paths to the left, apply the arrow on the left side of the EXIT Sign.  

iii.

 

For Exit paths to the right, apply the arrow on the right side of the Exit Sign. 

iv.

 

If Exit paths are located to the left and right, apply both arrows to the EXIT Sign. 

 

FOR FLAG MOUNT 

 

2.

 

Place the EXIT Sign 

bracket

 in position and mark the screw hole locations. 

3.

 

If wall anchors will be required, drill 4ea 3/16” holes and install them at this time (Supplied). 

4.

 

Attach the EXIT Sign 

Bracket

 to the wall using the supplied #6 screws and anchors.  

5.

 

Drill two 3/32” holes in the sign face on the where indicated by the alignment dots near the end of the sign. 

6.

 

Slide the mounting bracket onto the side of the exit sign and align with the drilled holes. 

7.

 

Attach the ULTRA 50 EXIT sign to the bracket and secure into place by inserting the screws and tightening the acorn nuts 

which are supplied with the sign. 

 

FOR CEILING MOUNT 

 

2.

 

Place the EXIT Sign 

bracket

 in position and mark the screw hole locations. 

3.

 

If wall anchors will be required, install them at this time (Supplied). 

4.

 

Attach the exit sign Bracket to the ceiling using the supplied #6 screws and anchors.  

5.

 

Drill two 3/32” holes in the sign face where indicated by the alignment dots near the top of the sign. 

6.

 

Slide the mounting bracket onto the top exit sign and align with the drilled holes. 

7.

 

Attach the ULTRA 50 EXIT sign to the bracket and secure into place by inserting the screws and tightening the acorn nuts 

which are supplied with the sign. 

 

FOR T-BAR MOUNT 

 

2.

 

Place the EXIT Sign 

bracket

 in position and attach using the supplied T-Bar clips. 

3.

 

Slide the mounting bracket onto the top exit sign and align with the pre-drilled holes. 

4.

 

Attach the ULTRA 50 EXIT sign to the bracket and secure into place by inserting the screws and tightening the acorn nuts 

which are supplied with the sign.

 

B R I G H T  PAT H  L I G H T I N G ,   I N C .

Ph. 559-443-7300

877-343-7300

2910 E. Heaton  Ave.

Fresno, CA 93721

www.bplighting.com

SAVE THESE INSTRUCTIONS 

Summary of Contents for ultra50

Page 1: ......

Page 2: ......

Page 3: ...igns are for INDOOR use only sunlight liquid spray or temperature outside the range 10ºC 40ºC 70º 160ºF Check with your applicable installation codes such as NFPA 101 Life Safety Code to perform periodic visibility tests Should any changes in your external lighting types or lighting levels occur make sure that the BPL ULTRA50 EXIT sign is still being illuminated with minimum 5 foot candles 54 lux ...

Page 4: ...k the screw hole locations 3 If wall anchors will be required drill 4ea 3 16 holes and install them at this time Supplied 4 Attach the EXIT Sign Bracket to the wall using the supplied 6 screws and anchors 5 Drill two 3 32 holes in the sign face on the where indicated by the alignment dots near the end of the sign 6 Slide the mounting bracket onto the side of the exit sign and align with the drille...

Page 5: ...nt Slide the frame base onto the top frame piece Center the base and secure it into place by tightening the set screw which is accessible through the center hole in the bottom of the base Go to steps 6 9 Flag Mount continued Remove the set screw from one of the corner angle brackets on the previously removed frame side Remove the corner bracket Slide the frame base onto the frame side Center the b...

Page 6: ... D E E F 3 16 Set screws 9 pieces Corner Bracket 4 pieces 8 5 Aluminum sides 2 pieces 14 25 Aluminum sides 2 pieces 7 Base Bracket 1 piece Surface Mount Spacers 4 pieces Spacers included with surface mount frames only ...