-26-
Electrical Adjustments
1. Receive the 16-step gray scale computer signal with
Input 3 [video]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+) and
chassis ground (-).
4. Select group no. “
4
”, item no. “
0
” and change data
value to adjust waveform “
a
” to be minimum ampli-
tude.
5. Connect an oscilloscope to test point “
TP561
” (+) and
chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
7. Connect an oscilloscope to test point “
TP501
” (+) and
chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
(a)
White Level
⁄4
Video Gain adjustment
1. Receive the 16-step gray scale computer signal with
Input 3 [Video]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+)
and chassis ground (-).
4. Select group no. “
4
”, item no. “
12
” and change data
value to adjust amplitude “
a
” to be
9.8
±0.1V.
(a)
black level
black level
⁄5
Video black Level adjustment
1. Receive the black 0% component 480i video signal
with
Input 3 [Component]
mode.
2. Enter the service mode.
3. Select group no. “
5
”, item no. “
11
” and change data
value to adjust the
green
noise on the screen to the
deepest green.
⁄6
Component Y pedestal adjustment
1. Receive the white 100% component 480i video signal
with
Input 3 [Component]
mode.
2. Enter the service mode.
3. Select group no. “
5
”, item no. “
18
” and change data
value to adjust the
magenta
noise on the screen to
the deepest magenta.
⁄7
Component A/D reference voltage
(top side) adjustment
1. Receive the black 0% component 480i video signal
with
Input 3 [Component]
mode.
2. Enter the service mode.
3. Select group no. “
5
”, item no. “
12
” and change data
value to adjust the
blue
noise on the screen to the
deepest blue.
4. Select item no. “
13
” and change data value to adjust
the
red
noise on the screen to the deepest red.
⁄8
Component Cb/Cr pedestal adjustment
1. Receive the 16-step gray scale component 480i sig-
nal with
Input 3 [Component]
mode.
2. Enter the service mode.
3. Connect an oscilloscope to test point “
TP531
” (+) and
chassis ground (-).
4. Select group no. “
4
”, item no. “
0
” and change data
value to adjust waveform “
a
” to be minimum amplitude.
5. Connect an oscilloscope to test point “
TP561
” (+) and
chassis ground (-).
6. Select item no. “
1
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
7. Connect an oscilloscope to test point “
TP501
” (+) and
chassis ground (-).
8. Select item no. “
2
” and change data value to adjust
waveform “
a
” to be minimum amplitude.
(a)
White Level
⁄9
Component Gain adjustment
Summary of Contents for MP-45
Page 60: ...60 IC Block Diagrams BH3540 Volume Control IC1652 BA7078AF Sync Detector IC5304...
Page 64: ...64 IC Block Diagrams LB1641 Motor Drive IC1602 IC1611 LB1645 Motor Drive IC1601...
Page 66: ...66 M62393 D A IC212 M62399 D A IC7801 IC Block Diagrams ML60851 USB Interface IC9801...
Page 108: ...MR3 MP 45t00 Mechanical Parts List 108 68 45 23 24 45 45 45 68 a 68 b 23 b 23 a 23 c 24 a 23 d...
Page 116: ...Diagrams Drawings MR3 MP 45t00...