-20-
■
Lamp Replacement
The LAMP REPLACEMENT indicator will illuminate
when the total lamp used time reaches 2000 hours.
The total lamp used time is calculated by using the
below expression,
Total lamp used time =
T
eco
+
T
normal
(1+1/3)
T
eco
: used time in the Eco mode
T
normal
: used time in the Normal mode
This is to indicate that lamp replacement is required.
You can check the lamp used time following to the
below procedure.
1
Press and hold the
e
button on the projector for more
than 20 seconds.
2
The lamp used time in each normal mode and eco
mode and total used time are displayed on the bot-
tom right corner of the screen briefly.
WARNING:
- For continued safety, replace with a lamp assembly of the same type.
- Allow the projector to cool for at least 45 minutes before you open the
lamp cover. The inside of the projector can become very hot.
- Do not drop the lamp module or touch the glass bulb! The glass can
shatter and cause injury.
Procedure
1
Turn off the projector and disconnect the AC cord. Allow the projector to
cool for at least 45 minutes.
2
Loosen 1 screws with a screwdriver and open the lamp cover.
3
Loosen 2 screws and pull out the lamp assembly by grasping the handle.
4
Replace the lamp assembly securely and tighten 2 screws.
5
Close the lamp cover and tighten 1 screw.
6
Connect the AC cord to the projector and turn on.
Note:
- Do not reset the Lamp Replace Counter, except after lamp is replaced.
- The projector can not be turned-on with lamp cover removed, because
when the lamp cover is removed, the interlock switch is also released to
switch off the mains power for safety.
7
Reset the Lamp Replace Counter, see below explanation
.
1
Turn the projector on, and press the
MENU
button
and the on-screen menu will appear. Press the
7
or
8
button to move a red frame pointer to SETTING menu
icon.
2
Press the
e
button to move a red frame pointer to
“Lamp counter reset” and then press the
SELECT
button. The message “Lamp replace counter reset?” is
displayed. Move the pointer to [Yes] and the press the
SELECT
button.
3
Another confirmation dialog box appears and select
[Yes] to reset Lamp Replace Counter .
Please refer to the owners manual for further informa-
tion.
Recommendation
Should the air filter become clogged with dust particles,
it will reduce the cooling fan’s effectiveness and may
result in internal heat build up and short lamp life. We
recommend cleaning the air filter after the projection
lamp is replaced.
Refer to “Air Filter Cleaning”.
Lamp Age
Normal :
0100
HOURS
Eco:
0025
HOURS
0158
HOURS
Total lamp used time
How to reset Lamp Replace Counter
How to check Lamp used time
Lamp cover
Lamp Assembly
Handle
ORDER REPLACEMENT LAMP
Type No.
Service Parts No.
POA-LMP53
610 303 5826
Summary of Contents for CP-320t
Page 50: ...50 IC Block Diagrams AD8075 Selector IC201 AD8183ARU Selector IC1201 AN7513 Audio Amp IC5001...
Page 51: ...51 AN5870SB RGB SW IC5201 IC Block Diagrams AD9884AKS A D IC8201...
Page 54: ...54 IC Block Diagrams CXD3526GG LCD Driver Timing Generator IC401 FA5502 P F Control IC611...
Page 55: ...55 LA7217 Sync Separator IC5361 M62392 D A IC3561 IC Block Diagrams...
Page 56: ...56 NJM2284M Switch IC2101 IC Block Diagrams M62393 D A IC281 IC7801...
Page 82: ...MA3 CP 320t00 Electrical Parts List 82 Key No Part No Description Key No Part No Description...
Page 84: ...MA3 CP 320t00 84 47 44 44 47 44 44 Mechanical Parts List 47 57 56 47 47 Optical Parts...
Page 85: ...MA3 CP 320t00 85 44 44 54 67 Red 68 Green 69 Blue 45 45 45 Mechanical Parts List...
Page 87: ...MA3 CP 320t00 87 52 a 52 46 46 46 46 52 Mechanical Parts List...
Page 88: ...MA3 CP 320t00 88 Mechanical Parts List 58 70 63 71 57 60 65 59 64 66 51 55 62...