Appendix A: Dispense Mode Settings Menu 

(Start at the bottom of this page) 

Set max current. 

Set suck back (number of revolutions). 

Set acceleration (0 to 255) 

Set deceleration (0 to 255). 

Set direction (CW or CCW). 

Activate lid and stall detection inputs. 

Reset to factory settings. 

Exit settings menu 

Enter speed for calibration run. 

Directly enter ml per revolution. 

Enter dispensed volume. 

Save or  
discard. 

Save value. 

Discard value. 

Start calibration run. 

Stop calibration run. 

Not activated. 

Activated. 

Not activated. 

Activated. 

Change mode, see section 3.1 

Settings   Down    Up     Enter   Next Menu 

Calibration, dry (from pump data) 
or wet (actual measurement).  

www.boxerpumps.com 

6900.011-01 

Page 10

Appendix B: Dose Mode Settings Menu 

(Start at the bottom of this page) 

Set max current. 

Calibration, dry (from pump data) 
or wet (actual measurement).  

Enter speed for calibration run. 

Directly enter ml per revolution. 

Enter dispensed volume. 

Save or  
discard. 

Save value. 

Discard value. 

Set suck back (number of revolutions). 

Set acceleration (0 to 255) 

Set deceleration (0 to 255). 

Set direction (CW or CCW). 

Activate lid and stall detection inputs. 

Not activated. 

Activated. 

Not activated. 

Activated. 

Reset to factory settings. 

Exit settings menu 

Set dose speed. 

Set dose interval. 

Set number of cycles 

Set hours. 

Set minutes. 

Set seconds. 

Start calibration run. 

Stop calibration run. 

Change mode, see section 3.1 

Settings   Down    Up     Enter   Next Menu 