
Esprit 2 1000 230V Operating Instructions.
Esprit 2 1000 230V Operating Instructions.
2
7
Unit Specification
Unit
Esprit 2 1000
Stored Energy (Max)
1000Ws
Charge Time (Full Power 230V)
2.37 secs.
Supply Voltage AC
190-250 VAC 50Hz
Voltage Stabilisation
+/- 1%
Modelling Lamp
Max 275W
Ready Indication
100%
Fuse 10A
(F)
Sync Volts
15V
Photocell On/Off
Sounder On/Off
Modelling Power Control
Int/Off/Cont (Independent & Fully variable)
Guide Number – Full Power 50
°
Keylite, 100
ISO
137.2
Flash Duration (Full Power) T=0.5
1/1500
Flash Colour Temperature
Apx. 5600K UV coated as std.
Flash Power Control
Full to 1/32, 5 F stops fully variable
Recommended Modelling Lamp
250W 240V Halostar
250W 220V Halostar
275W 220/240V Photoflood
BW-1024
BW-1024/A
BW-1824
Flash Tube Assembly
Clear
UV Coated
BW-2980
BW-1079
Dimensions L=450mm
W=145mm
H=145mm
Weight 4.5Kg
Due to our policy of constant product improvement Bowens International reserve the right to
change equipment specifications without notice.
1. Fuse (+ Spare Fuse)
2. Mains
Inlet
3. Modelling Lamp Control Switch
4. Sync
Socket
5. Mains On/Off Switch
6. Photocell
On/Off
7. Sounder
On/Off
Fig.2
1
5
3
2
4
6
1
2
5
4
7
6
3
Fig.1
1. Latch Knob
2. Photocell Cover
3. ‘Ready’ Indicator
4. Flash Power Control
5. Test/Open Flash
6. Modelling Power Control