Bowens ESPRIT digital DX 250 Operating Instructions Manual Download Page 4

Esprit Digital Operating Instructions 

 

13 

QUICK START GUIDE 

The Esprit Digital is very simple to operate once the user has become familiar with the controls.  
Detailed operating instructions are given after this Quick Start Guide. 

Mounting 

Select a stand or support system of suitable weight and dimensions to ensure stable operation of 
the unit.  The mounting bush on the “L” bracket allows the unit to be mounted two different ways 
(Fig. 3).  Method A is preferred, however method B can be used if the light needs to point 
downwards.  Ensure that the clamp knob is fully tightened.  

 

Figure 3 

Protective Cap 

Push the latch knob back towards the rear of the unit, rotate and remove the plastic protective 
cap.  Always refit the cap when transporting the unit to avoid damaging the flash tube or modelling 
lamp.  NEVER operate the unit with the cap still in place. 

Modelling Lamp 

Ensure that the unit is switched off and disconnected from the supply.  Confirm that the lamp and 
flash tube are securely fitted, particularly before first use or after transporting the unit. Refer to the 
section on fitting the modelling lamp if required. 

Reflector/Accessory System 

A range of reflectors and accessories are available for the Esprit units. Slide the neck of the 
reflector/accessory over the front of the unit. Align the three pegs with the three slots in the 
retaining ring, press down and turn clockwise to lock. Ensure that the latch knob is in the closed 
position. 

To remove reflector, push the Latch Knob towards the rear of the unit, turn the reflector fully 
counter-clockwise and withdraw. 

Note:

 A Photoflood or Halostar bulb with a maximum wattage of 275W is recommended for use in 

Esprit Digital units. The manufacturer will not accept liability for the use of any lamp with a rating 
exceeding 275W. 

The unit has a built-in ‘soft start’ feature to enhance lamp life but this can be improved further by 
dimming or turning the lamp OFF whenever possible.  This will also reduce the heat dissipated by 
the unit.  Avoid moving or knocking the unit when the lamp is switched on or when it has just been 
turned off since lamp filaments can be damaged when hot. 

FLASH TUBE REPLACEMENT 

Ensure that the unit is switched off and disconnected from the supply before replacing the flash 
tube assembly. Wait a few minutes for the lamp and tube to cool and for the unit to self-discharge, 
it is advisable to leave the unit for as long as possible before changing the flash tube.  

Remove the protective cap and unwind the twisted Trigger wire from the flash tube support.  

Carefully pull the flash tube assembly out of the unit. To replace the assembly, hold the 
replacement flash tube assembly as shown in Fig.4, taking care to support both legs of the tube. 
Locate the two brass sockets onto the plugs in the front of the unit and, gently but firmly, push the 
flash tube into position. Finally wind the trigger wire around the flash tube support. 

Always replace with the correct flash tube assembly: 

BW-2032 for UV coated or BW-2030 for clear. 

 

Figure 4 

 

 B 

Summary of Contents for ESPRIT digital DX 250

Page 1: ...R THE 250DX 500DX 117V ESPRIT DIGITAL INSTRUCTIONS BWL 0322 1 10 1 02 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH UNITED KINGDOM Tel 44 0 1255 422807 Fax 44 0 1255 436342 www bowensinternational com ...

Page 2: ...ll control 12 channels No depends on transmitter Guide Number Full power 50 Keylite ISO 100 60m 82m Flash Duration Full Power t 0 5 1 1100s 1 700s Flash Colour Temperature Approx 5900K Clear tube Approx 5300K UV coated Approx 5900K Clear tube Approx 5300K UV coated Flash Power Control Full to 1 32 5 f stop in 1 10 increments Full to 1 32 5 f stop in 1 10 increments Recommended Modelling Lamp 250W ...

Page 3: ... Confirm that the fuse is intact and if in doubt replace A spare fuse is fitted in the fuse holder always replace with a fuse of the correct type and rating If the fuse blows immediately the unit is switched on remove the modelling lamp replace the fuse and try again If the fuse blows again there is an internal fault The Control Panel Lights but Does Not come To READY If this happens then first co...

Page 4: ...he latch knob is in the closed position To remove reflector push the Latch Knob towards the rear of the unit turn the reflector fully counter clockwise and withdraw Note A Photoflood or Halostar bulb with a maximum wattage of 275W is recommended for use in Esprit Digital units The manufacturer will not accept liability for the use of any lamp with a rating exceeding 275W The unit has a built in so...

Page 5: ...ot to damage the flash tube assembly The flash tube is very delicate avoid unnecessary handling of the glass tube Always switch off and disconnect from the supply before changing the flash tube assembly AC Supply The unit operates from an AC Line voltage within the range 95V to 130V with a nominal frequency of either 50Hz or 60Hz Ensure that the Power ON OFF switch on the unit is set to OFF Use a ...

Page 6: ...l the display changes to show one of the values below Release the button If the SOUNDER is on it will sound continuously while the FUNCTION button is held down Now momentarily press the FUNCTION button to scroll through the options until the desired one is reached as follows Display Range X X Description X X X 0 0 0 to 9 9 9 Firmware version di X 1 to 9 Display brightness value Use UP or DOWN to a...

Page 7: ...e 1 is minimum and 9 is the maximum Use UP or DOWN to adjust Default factory setting is di 7 UP DOWN Buttons Select the required FUNCTION as detailed above Single presses of the UP or DOWN buttons will increment or decrement the value by one Hold the appropriate button down to automatically increment or decrement the value Release the button when the required value is reached and then use momentar...

Page 8: ...tomatically discharges the capacitors when the power is reduced The READY indicator flashes while the unit is dumping The user may select one of two DUMP methods by means of the OPTIONS sub menu See OPTIONS for a description of how to access this mode The default factory setting is Fd 0 In this mode the unit resistively dumps excess energy whenever the flash setting is reduced This is a relatively...