Bowens BW-7600 Operating Instructions Manual Download Page 6

www

.bowens.co.uk

15

www

.bowens.co.uk

Function Overview (cont.)

6

QU
A

DX

Advanced Options

The QUADX features a number of advanced options.  

These are accessed by selecting “Advanced

Options” from the ‘Main” selection menu.

The following is a brief list of features available, which are described in greater detail from page 12.

1.

Speaker Set-up.

- Control Ready

, Error and keypad tones.

2.

Alternate 

Unite.

- Choose to display power in Joules (Ws) or as a percentage.

3.

Brightness.

- Control the display brightness.

4.

T

ime Out Settings.

- Control the time before 

Auto-return to the main menu.

5.

Save/Recall

- Store and retrieve pack settings.

6.

Charge control

- Switch between 

Auto and Slow charge rates.

7.

Set-up Flash Mode

- Set 

T

rigger Delays, Skip 

T

riggers and Multiple 

T

riggers.

8.

Reset Job Counter

- Clear the job count.

T

riggering System

The unit may be triggered from the following sources.

1.

A

Sync. plug in either of the 

3

4

” jack-type sockets will trigger the pack if the ‘READY’

LED is 

lit.  

The sync. supply is nom5V for low voltage camera operation.  

These sockets may

also be used with a Radio 

T

rigger

, Such as the Bowens Pulsar

, or I.R triggers to provide a 

synchronous trigger

.

2.

T

est/Open Flash button.  

The unit will only flash if the unit is charged and the ‘READY’

LED

is either lit or flashing.

3.

Remote Photo Cell.  When switched on, the unit will trigger in response to an external flash

of light, if the ‘READY’

LED is lit.  Ensure that the sloping panel is exposed clearly to the 

triggering light source.

4.

I.R Remote Control 

T

est.  With the I.R receiver switch, the unit can be triggered by the open

flash test button on the I.R Handset.

Adjust the FLASH and MODELLING controls to provide the desired settings and select any options

required.  Refer to the section on operation of the controls if required.  

T

est flash the unit by pressing

the ‘TEST’

button.

Excess energy is automatically dumped when the flash power setting is reduced.  Both increasing and

decreasing the power setting generates heat inside the unit.  

Therefore avoid repetitive Up and Down

power changes.

Refer to page 13 if you intend to make continuous use of the fast recycling feature of the unit.

NOTE: If the unit is left unused for six months or predominantly used at low power settings it is

recommended that the power be increased to maximum and the unit left switched on occasionally for

at least 30 minutes to help preserve the life of the capacitors.

Advanced Options Menu

Advanced Options       Setup Flash Mode       Multi-T

rigger

.

The Multi-T

rigger Mode allows the pack to fire a multiple number of times following a single trigger

signal.  

The number of times the pack will fire can be set in the range 2 - 50.  In addition, the time

between firing may also be set between 0.1 and 0.9 seconds.

Note that the user must ensure that the pack will recharge within the time specified as otherwise it will

not be READY

and will not fire as expected.

Selection and adjustment is performed using the       &       keys to scroll and       to select.  

The  >  character changes to  *  when an item is ready to change.

Advanced Options       Reset Job Counter

.

The QUADX pack has two flash counters.  

The total flash counter

, which can not be modified by the

user and the job counter

.  Both counters increment on every attempted flash.

The job counter may be used to record the number of flashes over a particular period by resetting its

value to zero before a session and then reading the value after the session.

T

o

 view the counter select:

Advanced Options        Reset Job Counter

T

o

 reset the job counter press        .

Summary of Contents for BW-7600

Page 1: ...UADX GENERATOR INSTRUCTIONS BWL 0335 2 08 05 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH UK Tel 44 0 1255 422807 Fax 44 0 1255 436342 www bowens co uk OPERATING INSTRUCTION...

Page 2: ...4 x Max 650W On Off On Off 6 6 f stop in 1 10 increments scaled 10 3000Ws 175 UV Coated Tube 1 1430s Full Power t 0 5 Approximate value indicated Approx 6500K UV Coated QUADX Head BW 7660 360mm 14 1 2...

Page 3: ...ire Warning Following a flash the unit will temporarily display READY on the red numeric displays for 5 seconds This serves as a convenient method of showing correct pack operation when two or more pa...

Page 4: ...reen there are three toggle controls to switch the photocell I R remote and modelling on or off To the right of the screen there is a pair of adjustment buttons to raise or lower the power from channe...

Page 5: ...n the unit is not ready There are three modelling modes Full Proportional and automatic 100 The Full and Automatic 100 modes also provide a bias control allowing all lamps to be controlled in ratio Ma...

Page 6: ...rols to provide the desired settings and select any options required Refer to the section on operation of the controls if required Test flash the unit by pressing the TEST button Excess energy is auto...

Page 7: ...t HINT Whenever a flash mode is enabled the default menu will show Progmd on the default menu in order to show a mode is in place All modes are switched OFF after powering off the unit Advanced Option...

Page 8: ...ing the pack the user must consider the electrical load placed upon the mains supply As a worst case with four heads plugged in using 650W of modelling each the mains supply could be overloaded with c...

Page 9: ...power Advanced Options Alternate Units to toggle between Joules and Percentage ADVANCED OPTIONS RESET JOB COUNT SPEAKER SETUP ALTERNATE UNITS The Information Menus The DEFAULT MENU shown here display...

Page 10: ...nged to start at a low power working upwards or alternatively may begin at a high power and work downwards The first thing to do when using bracketing is to ensure that you have set the bracket step S...

Reviews: