11. 

Fuse (Fig.1. 3) 

The modelling and flash circuitry is protected by a single 5 amp (F) 20mm 
fuse mounted on the rear panel. Never replace the fuse with one of a different 
rating. As the fuse may blow when the modelling lamp fails always check the 
fuse when replacing bulb. A spare fuse is supplied in the fuse holder. Always 
switch OFF the Esprit 250 before changing the bulb or fuse. 

 

12. 

Fitting / Removing A Reflector 

A range of reflectors is available for the Esprit 250. To fit, slide the neck of 
the reflector over the front of the unit. Align the three pegs on the reflector 
with the three slots in the retaining ring. Press down and turn clockwise to 
lock. 
 
To remove reflector, press Latch Knob (Fig.2. 1)  turn the reflector fully anti-
clockwise and withdraw. 
 
If an umbrella is to be used a ‘Spill Kill’ (BW-1885) should be fitted and the 
umbrella inserted through the hole in the mounting bracket on the Spill Kill 
and locked into position with the knurled screw. 
 
Note:  Take care when fitting / removing reflectors not to damage the 
flashtube assembly. The flashtube is very delicate, avoid unnecessary handling 
of the glass tube. Always switch off and disconnect from mains supply before 
fitting / changing the flashtube assembly. 

 

Warning High Voltage 

 

Do not touch the flashtube assembly for thirty minutes after 
disconnecting from supply. 

 

13. 

Replacement Of Flashtube 

Ensure that the unit is switched off and disconnected from the mains supply 
and then wait thirty minutes before touching / removing flashtube. Remove the 
protective cap and unwind the twisted Trigger wire from the flashtube support. 

Gently pull flashtube assembly out of the unit. To replace the flashtube, 
holding the flashtube as shown in Fig.3 and taking care to support both legs of 
the tube,gently but firmly, push the flashtube into position. Wind the Trigger 
wire around the flashtube support. 
 

14. Operation 

Mount the Esprit 250 on selected support system. The mounting bush on the 
‘L’ bracket allows for two possible ways of mounting to the stand / support 
(Fig.4). Method B may be found useful if the light is required to point down. 
Fit the reflector and connect to supply. 
 
Plug in the sync cord and connect to camera shutter at ‘x’ synchronisation. 
Alternatively, plug in Infra Red Receiver or Omnicell. Switch ON and select 
modelling lamp ON or OFF and flash power required. When the unit is ready 

Summary of Contents for BW-1070

Page 1: ...ESPRIT 250 BW 1070 OPERATING INSTRUCTIONS...

Page 2: ...g Instructions 2 1 Sync Socket 2 Mains Inlet 3 Fuse Spare Fuse 4 Mains On Off Switch 5 Modelling Lamp Control Switch 1 Latch Knob 2 Flash Power Control 3 Ready Indicator 4 Photocell Cover 5 Test Open...

Page 3: ...ging the fuse Never replace with a fuse of a different rating A spare 5A fuse is fitted in the fuse holder iv Switch off and disconnect supply before changing fuse modelling bulb or flashtube v Do not...

Page 4: ...hat can be fired when only 80 charged This ensures that every flash is identical 9 Synchronisation Open Flash For testing or multiple flash applications the Open Flash Pushbutton Fig 2 5 can be used T...

Page 5: ...ube is very delicate avoid unnecessary handling of the glass tube Always switch off and disconnect from mains supply before fitting changing the flashtube assembly Warning High Voltage Do not touch th...

Page 6: ...Bowens Esprit 250 Operating Instructions 6 to fire the green LED Fig 2 3 will light Press Open Flash Pushbutton Fig 2 5 and check that the unit operates correctly...

Page 7: ...Bowens Esprit 250 Operating Instructions 7...

Page 8: ...100 of charge Fuse 5A F Sync Volts 15v Guide Number Full Power 50 Keylite 100 ISO 60 Flash Duration Full Power T 0 5 1 1100th Flash Colour Temperature Approx 5300K UV coated Flash Power Control Full t...

Page 9: ...9 Esprit 250 Instructions BW 1070 BWL 0172 5 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH Tel 44 0 1255 422807 Fax 44 0 1255 436342...

Reviews: