background image

Quick guide 

Summary of Contents for ARC 350

Page 1: ...Quick guide...

Page 2: ...s quick guide is a brief summary of the most important working steps and information It does not replace the instructions for use For detailed information please read the instructions for use for the...

Page 3: ...ts 8 2 3 Back of the generator 10 3 Start up 3 1 Switching on the device 11 3 2 Monopolar mode 12 3 3 Bipolar mode 13 3 4 Plug Cut COMFORT 14 3 5 Selecting the neutral electrode 15 4 Operation 4 1 Ope...

Page 4: ...aecology Hand surgery ENT Cardiac surgery including open heart surgery Neurosurgery Pediatric surgery Plastic surgery dermatology Thoracic surgery Orthopedics Urology including transurethral resection...

Page 5: ...ot switch Instruments monopolar and bipolar connecting cable Neutral electrode for monopolar applications With cable holder 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5...

Page 6: ...vation indicator 3 Monopolar Effect button 4 Monopolar Maximum output power button 5 Monopolar sockets 6 Neutral electrode connection 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OP...

Page 7: ...indicator 8 Bipolar Maximum output power button 9 Bipolar Effect button 10 Bipolar sockets 5 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECTION AND CLEANING 6 TE...

Page 8: ...ar sockets Neutral electrode connection International 3 pin international Erbe 5 mm Bovie 4 mm socket Depending on configuration 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATI...

Page 9: ...ion 2 pin international 28 58 mm 2 pin international 28 58 mm Erbe VIO ICC Depending on configuration 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECTION AND CLEAN...

Page 10: ...5 Fiber optic cable signal input socket 6 Fiber optic cable signal output socket 7 Ethernet connection 8 Mains power switch The following connections should only be used by service technicians and fo...

Page 11: ...est The main display screen appears A message appears explaining how to operate the device The ARC 350 is ready for operation The parameters of the last saved program are shown on the display 3 1 SWIT...

Page 12: ...electrode handpiece up to one of the two monopolar sockets 3 2 MONOPOLAR APPLICATION The foot switch must be connected when instruments without a finger switch are used 1 USING THE ARC 350 2 DISPLAY A...

Page 13: ...ith a bipolar connecting cable into one of the two bipolar sockets Connect the foot switch 3 3 BIPOLAR APPLICATION 1 USING THE ARC 350 2 DISPLAY AND CONTROL ELEMENTS 3 START UP 4 OPERATION 5 DISINFECT...

Page 14: ...vailable in monopolar and bipolar versions BOWA COMFORT function is available for BOWA COMFORT instruments with adjustable parameters Preset values are available and can be individually adjusted BOWA...

Page 15: ...er conductivity in the direction of the fibrils EASY For monitoring of split neutral electrodes BABY For monitoring of split pediatric electrodes MONO For selection of one piece neutral electrodes 2 3...

Page 16: ...up white The indicator starts to flash when settings are changed 2 Effect The effect of the electrosurgical dissection or coagulation can be set using the Effect button 3 Max Watt Press max Watt to ad...

Page 17: ...ontact 10 Programs Calling up of stored program selection 11 The bipolar activation indicator lights up yellow or blue as soon as an instrument is activated in the respective socket If an instrument i...

Page 18: ...ndicator lights up white When the active socket is used the current type is displayed in the activation indicator in blue and yellow 2 Unused socket If there is no instrument connected to the socket o...

Page 19: ...to enter the mode selection directly Monopolar cutting modes NAME APPLICATION SUITABLE INSTRUMENT Standard Cutting with low electrical tissue resistance Cutting or preparation of fine structures Needl...

Page 20: ...Dynamic pulse sequence for practiced users Polypectomy snares GastroLOOP 3G Removal of polyps with polypectomy snares via flexible endoscopes Dynamic pulse sequence for seasoned users Polypectomy sna...

Page 21: ...ndency Knife electrodes Spatula electrodes Needle electrodes Spray Coagulation of diffuse bleeding Ball electrodes Knife electrodes Spatula electrodes Needle electrodes Laparoscopy Laparoscopy Arthros...

Page 22: ...Vaporization of prostate tissue TUR VAP Resectoscope monopolar Resection snare Rollerblade electrode Cardiac Mammary Breast surgery Cardiac surgery Knife electrodes Cardiac Thorax Thoracic surgery Kni...

Page 23: ...bipolar Resection snare Bipolar scissors Dissection Coagulation and cutting of tissue Bipolar scissors VaporizationR Hysteroscopy Transurethral resection of the prostate TURP Transurethral resection o...

Page 24: ...ipolar vessel sealing open and laparoscopic TissueSeal PLUS NightKNIFE LIGATOR ERGO 310D ERGO 315R ARCSealL Bipolar vessel sealing open and laparoscopic ERGO 310D ERGO 315R TissueSeal PLUSL Vessel sea...

Page 25: ...zationR Hysteroscopy Transurethral resection of the prostate TURP Transurethral resection of the bladder TURB Vaporization of prostate tissue TUR VAP Resectoscope Rollerblade electrode Vaporization el...

Page 26: ...m power Set the power in individual steps using the and buttons Press OK to confirm your selection Press any key outside the selection field to return to the main screen without changing the selection...

Page 27: ...ding button Confirm your selection with OK The foot switch can be used to change between the foot switch levels Press the orange switch and change the socket The activation is visualized by the colori...

Page 28: ...infectant approved by the manufacturer for surface cleaning Cleaning agents and disinfectants Wipe with a sponge or cloth moistened with clean water Dry with a clean lint free cloth 1 2 3 Make sure th...

Page 29: ...75 mm Weight 12 5 kg Classification according to EU Directive 93 42 EEC IIb Protection class according to EN 60601 1 I Type of applied part according to EN 60601 1 CF CE mark as per EU Directive 93 42...

Page 30: ...30...

Page 31: ...31...

Page 32: ...e reserve the right to make technical and structural amendments Copyright of BOWA electronic Gomaringen BOWA electronic GmbH Co KG Heinrich Hertz Strasse 4 10 72810 Gomaringen I Germany Phone 49 0 707...

Reviews: