Important!

 

Do not leave system unattended while in use. 

 

 

Misuse or abnormal operating conditions can produce hot steam. 

Steam can cause damage to water bags and risk of injury including burns.  Temperatures 
exceeding 212° F (100 C) are possible. 
 

In the event that steam is produced

 

during operation

 (indicated by a gurgling or hissing 

sound similar to a coffee maker brewing) First, immediately remove coil from heat 
without directly touching heated parts, then follow the troubleshooting 
recommendations in this manual. 

 

 
 
14.

 

REMOVE coil from the heat source using 
a stick BEFORE water level reaches the 
outlet port of supply bag.

 

 
 

Note:   

There will remain a small amount 

of water in the bag below the outlet 
port.  The water will not completely 
empty from the bag. 

 
 
 
 

15.

 

See - Shower Operation (pg. 13)

 

 
 

 

 

 

12  

 

 

DOC: 100-032E

Questions?

800.753.9943

[email protected]

www.boundarytec.com

© 2015 BoundaryTEC, LLC.

 

Heating Recommendations 

 The 

ShowerCoil

 thermostat valve is very effective in controlling the heated water temperature across a 

range of temperature and conditions.  However, to ensure accurate water temperatures, follow the heating 
recommendations below. 
 

 

 

N/R 

Not Recommended 

Important! 

Do not exceed maximum recommended heating intensity.   Doing so can 
produce water temperatures which exceed temperature setting. 

Note 

Normal heating times for a 

full bag

 of water will range from 

10-18 minutes

.  

If actual times are outside of this range, recheck the heat intensities above 
and refer to the Troubleshooting section of this manual. 

Tip 

A fresh camp fire with flames passing over the coil will give the best heating 
results. 

Tip 

Insulate the lower (heated) water bag from the ground by placing it on a 
towel or foam pad when the outside temperature is cool (<65

°

F / <18 C). 

Summary of Contents for ShowerCoil 1530A

Page 1: ...r outdoor use only Operate only in well ventilated areas clear of flammable materials Do not leave heating system unattended while in use Observe all applicable federal state and local regulations whe...

Page 2: ...quipment damage Do not use mouth to siphon or purge water through the heating system Doing so with a hot system can cause severe burns of the mouth and throat Do not leave heating system unattended wh...

Page 3: ...er structure Remember to dispose of wash gray water responsibly Wash yourself or dishes at least 150 feet away from streams or lakes to avoid soap run off into a natural water source Check with the ap...

Page 4: ...ean water Note If collecting water from a lake or river hold the bag as shown below and horizontally scoop undisturbed water a few inches below the surface This technique allows the cleanest water to...

Page 5: ...IME WITHOUT WATER FLOWING THROUGH SYSTEM Doing so can damage or melt the heating coil and cause a risk of injury including burns 10 DOC 100 032E Questions 800 753 9943 support boundarytec com www boun...

Page 6: ...t completely empty from the bag 15 See Shower Operation pg 13 12 DOC 100 032E Questions 800 753 9943 support boundarytec com www boundarytec com 2015 BoundaryTEC LLC Heating Recommendations The Shower...

Page 7: ...f the trapped air 14 DOC 100 032E Questions 800 753 9943 support boundarytec com www boundarytec com 2015 BoundaryTEC LLC 3 Roll over the top edge of the bag 4x towards the front translucent side of t...

Page 8: ...horoughly and allow to dry before storing or using Chart shows approximate times in which the temperature of a full water bag drops 3 F 1 7 C 16 DOC 100 032E Questions 800 753 9943 support boundarytec...

Page 9: ...OC 100 032E Questions 800 753 9943 support boundarytec com www boundarytec com 2015 BoundaryTEC LLC Problem Possible Causes Solutions Water does not flow after interconnecting the heating system 1 Sup...

Page 10: ...ginal sales receipt This warranty does not cover damage from normal wear and tear of parts This warranty does not cover damage resulting from misuse or modification of the Product use contrary to the...

Reviews: