23 June 2015
Version 1.7
Page 25-57
25.22.
Checking compressor
Steps
To check the compressor, follow the steps in
STEP ACTION
1.
Read the pressure on the reduce valves (see
Pression reduce circuit (1)
1 bar
Crush security (2)
5 bar
Blowing off milk (3)
2 bar
System pressure (4)
6 bar
Figure 25-63 Reduce valves
2.
Adjust, if required, the pressure until the correct value with the knob at
the upper side of the reduce valve (see
Pull the knob up (1) and turn the knob (2) to adjust the pressure.
Push the knob down to lock.
1
3
4
2