CALIBRATING CAMERA
13.1.
Actions before calibrating the camera
Steps
Before calibrating the camera, follow the steps in
STEP
ACTION
1.
Switch the milking box to
SERVICE
control mode.
2.
Close the
GUPPY
program.
3.
4.
Add a backup folder in
C
:\
AMS
\
GUPPY
with the name
BACKUP
DD
-
MM
-
YY
(day-month-year).
5.
Open the folder
C
:\
AMS
\
GUPPY
.
6.
Cut in this folder the next files (1) (see
):
Calib.cal
Calib.lut
Lut.$$$
7.
Paste these files in the backup folder.
Figure 13-1 Moving files
Scheme 13-1 Actions before calibrating