Boulevard DVTL41BP90N-1 Installation Instructions And Owner'S Manual Download Page 3

33591-1-0414

Page 3

Proper Log Placement

Log placement is critical to proper burner performance. Logs must 

be correctly positioned. The photos in this manual show the proper 

pinned position for logs on this set. Owners need to be shown proper 

log placement and instructed not to move the logs. 
Logs must fit firmly onto the burner when positioned as shown in 

the photos. Misformed logs or logs with sloppy pin holes must be 

replaced.

Proper Placement of Glowing Embers

Glowing Embers can be added to burners for a glowing ember effect. 

It must be positioned only on top of the burner. The photos in this 

manual  show the proper placement of glowing embers.

Make Owners Aware of Proper Log Set Operation

Properly installed and properly maintained log sets do not deposit 

soot on the logs. If users see soot appear on a log, call for service. 

Do not continue to operate the log set.

Qualified Installing Agency

Installation  and  replacement  of  gas  piping,  gas  utilization 

equipment or accessories and repair and servicing of equip

-

ment shall be performed only by a qualified agency. The term 

"qualified agency" means any individual, firm, corporation, 

or company that either in person or through a representa

-

tive is engaged in and is responsible for (a) the installation, 

testing, or replacement of gas piping or (b) the connection, 

installation, testing, repair, or servicing of equipment; that is 

experienced in such work; that is familiar with all precautions 

required, and that has complied with all the requirements of 

the authority having jurisdiction.
The  installation  must  conform  with  local  codes  or,  in  the 

absence of local codes, with the 

National Fuel Gas Code, 

ANSI Z223.1/NFPA54

.*

*Available from the American National Standards Institute, Inc. 11 West 

42nd St., New York, N.Y. 10018.

State of Massachusetts: 

The installation must be made 

by a licensed plumber or gas fitter in the Commonwealth 

of Massachusetts.
Sellers of unvented propane or natural gas-fired supple

-

mental room heaters shall provide to each purchaser a 

copy of 527 CMR 30 upon sale of the unit.

Appliance Certification

This logset is design certified in accordance with American National 

Standard/CSA Standard ANSI Z21.88/CSA 2.33 and by Underwrit

-

ers Laboratories for use with a Direct Vent Gas Fireplace Heater 

and shall be installed according to these instructions.

IMPORTANT INSTALLATION GUIDELINES

GENERAL INFORMATION

Summary of Contents for DVTL41BP90N-1

Page 1: ...OD LOGS WARNINGS If the information in this manual is not followed ex actly a fire or explosion may result causing property damage personal injury or loss of life Do not store or use gasoline or other...

Page 2: ...1 0414 Page 2 TABLE OF CONTENTS Important Installation Guidelines 3 General Information 3 Log Identification 4 Log Placement 5 10 Master Parts Distributor List 11 How To Order Repair Parts 11 SECTION...

Page 3: ...agency means any individual firm corporation or company that either in person or through a representa tive is engaged in and is responsible for a the installation testing or replacement of gas piping...

Page 4: ...33591 1 0414 Page 4 LOG IDENTIFICATION TOP VIEW FRONT VIEW DESCRIPTION PART NUMBER Back Log A 33570 Left Logs B 33572 Cross Branch C 33573 Right Branch D 33571 Front Twig E 33574...

Page 5: ...e model number Glowing embers should be dime sized pieces that are fluffed up prior to placement onto the burner Asingle layer of glowing embers is sufficient do not over apply NOTE Once the installat...

Page 6: ...Back Log A onto the rear of the burner cover Center the log so that the ends of the log are approximately 2 inches from the sides of the firebox Note The back log may require some rotation so it rests...

Page 7: ...33591 1 0414 Page 7 TOP VIEW FRONT VIEW 2 Place the Left Log B onto the left pin on the Back Log A and angled down to the left wall of the firebox LOG PLACEMENT...

Page 8: ...33591 1 0414 Page 8 TOP VIEW FRONT VIEW 3 Place Cross Branch C onto the pin on the Left Log B and the middle pin on the burner cover LOG PLACEMENT...

Page 9: ...1 0414 Page 9 TOP VIEW FRONT VIEW 4 Place Right Branch D onto the right pin on the Back Log A and the right pin on the burner cover The left twig of the Righ Branch will rest on Cross Branch C LOG PLA...

Page 10: ...33591 1 0414 Page 10 TOP VIEW FRONT VIEW 5 Place Front Twig E onto the left pin on the burner cover as shown below LOG PLACEMENT...

Page 11: ...ranty parts All parts listed in the Parts List have a Part Number When ordering parts first obtain the Model Number and Serial Number from the name plate on your equipment Then determine the Part Numb...

Page 12: ...s Empire Comfort Systems Inc 918 Freeburg Ave Belleville IL 62220 If you have a general question about our products please e mail us at info empirecomfort com If you have a service or repair question...

Reviews: