Summary of Contents for DPX-620III

Page 1: ...DPX 620III 6 Ch dimmer pack User manual...

Page 2: ...Musikhaus Thomann Thomann GmbH Hans Thomann Stra e 1 96138 Burgebrach Germany Telephone 49 0 9546 9223 0 E mail info thomann de Internet www thomann de 23 06 2020 ID 107858 V2...

Page 3: ...1 3 Symbols and signal words 8 2 Safety instructions 10 3 Features 15 4 Installation and starting up 16 5 Connections and controls 19 6 Operating 23 7 Technical specifications 33 8 Plug and connectio...

Page 4: ...4 DPX 620III 6 Ch dimmer pack...

Page 5: ...vailable to all persons using this device If you sell the device to another user be sure that they also receive this manual Our products and user manuals are subject to a process of continuous develop...

Page 6: ...Use the search function in the electronic version to find the topics of interest for you quickly Online guides Our online guides provide detailed information on technical basics and terms Personal co...

Page 7: ...etterings for connectors and controls are marked by square brackets and italics Examples VOLUME control Mono button Texts and values displayed on the device are marked by quotation marks and italics E...

Page 8: ...y an arrow Example 1 Switch on the device 2 Press Auto Automatic operation is started 3 Switch off the device 1 3 Symbols and signal words In this section you will find an overview of the meaning of s...

Page 9: ...death or serious injury if it is not avoided NOTICE This combination of symbol and signal word indicates a pos sible dangerous situation that can result in material and environmental damage if it is...

Page 10: ...be improper and may result in personal injury or property damage No liability will be assumed for damages resulting from improper use This device may be used only by persons with sufficient physical...

Page 11: ...the unit They could swallow the pieces and choke Never let children unattended use electrical devices DANGER Electric shock caused by high voltages inside Within the device there are areas where high...

Page 12: ...ble ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation of the device must only be performed by qualified elec trical p...

Page 13: ...t source Keep the device away from naked flames NOTICE Operating conditions This device has been designed for indoor use only To prevent damage never expose the device to any liquid or moisture Avoid...

Page 14: ...the AC outlet is protected by a residual current circuit breaker Failure to do so could result in damage to the device and possibly injure the user Unplug the device before electrical storms occur and...

Page 15: ...rial connector n Digital control system n Control via DMX 512 n Single channel fuse 6 A n Phase correction for linear dimming n Individually adjustable dimmer curve n Power supply via 5 pin mains conn...

Page 16: ...dust and moisture during transportation or storage use the original packaging or your own packaging material suitable for transport or storage respectively Create all connections while the device is o...

Page 17: ...in electric shock and risk of fire and loss of life By all means you have to observe all electrical safety instructions applicable at the place of operation The device is designed for mounting in 19 r...

Page 18: ...Connect the output of the first DMX device to the input of the second one and so on to form a series connection Make sure that the output of the last DMX device in the chain is terminated by a resist...

Page 19: ...5 Connections and controls Front panel Connections and controls DPX 620III 6 Ch 19 dimmer pack...

Page 20: ...DMX signal is received 3 1 6 Voltage indicators of channels 1 6 The LEDs of active channels light solid green during operation 4 Display 5 CH 1 CH 6 Buttons for direct control of channels 1 6 6 Funct...

Page 21: ...d for 5 pin CEE plug 40 A Phase 3 230 V 8 Dimmer outputs 16 pin multi pin industrial connector note the device label when connecting the cables Rear panel Connections and controls DPX 620III 6 Ch 21 d...

Page 22: ...9 DMX IN DMX input 10 ANALOG Connections to control the device by a voltage in the range 0 V 10 V 11 DMX OUT DMX output Connections and controls 22 DPX 620III 6 Ch dimmer pack...

Page 23: ...ANGER Hazardous voltage Hazardous voltage may be present at cable ends and screw terminals The connection of screw terminals as well as all maintenance and repair work on the electrical installation o...

Page 24: ...C to reverse the direction of change Press one of the channel buttons UP or DOWN to increase or decrease the brightness of all channels together Pressing briefly results in changes with small incremen...

Page 25: ...ndent DMX addresses are independent of each other Confirm with MENU 4 In Start mode Use UP or DOWN to select the DMX address of channel 1 in a rage 1 512 Confirm with MENU 5 In Independent mode Use UP...

Page 26: ...channel whose DMX address is to be set Confirm with MENU Then select the DMX address for this channel from a range 1 512 Confirm with MENU and repeat the procedure for all channels 6 Press ESC to ret...

Page 27: ...ween options n LastHold Last setting is retained n Analog The analogue control signal input ANALOG is analysed n Progr 01 12 The built in automatic programmes are executed Confirm with MENU 4 In Progr...

Page 28: ...ividual maximum brightness Confirm with MENU 4 In All mode Use UP or DOWN to select the maximum brightness for all channels in a rage 70 100 Confirm with MENU In Independent Single mode Use UP or DOWN...

Page 29: ...an individual minimum brightness Confirm with MENU 4 In All mode Use UP or DOWN to select the minimum brightness for all channels in a rage 0 30 Confirm with MENU In Single mode Use UP or DOWN to fir...

Page 30: ...r curve and Single each channel can get an individual dimmer curve Confirm with MENU 4 In All mode Use UP or DOWN to select the dimmer curve from the options n Linear n S Curve n Non Dim n Square Conf...

Page 31: ...n S Curve n Non Dim n Square Confirm with MENU and repeat the procedure for all channels 5 Press ESC to return to the main menu Operating DPX 620III 6 Ch 31 dimmer pack...

Page 32: ...Menu overview Operating 32 DPX 620III 6 Ch dimmer pack...

Page 33: ...connections Power supply 16 pin multi pin industrial connector Signal output DMX 512 via 3 pin XLR socket Channel fuse Circuit breaker MCB per channel Trigger characteristic C Rated current 16 A Numb...

Page 34: ...llation 19 2 RU Dimensions W H D 482 mm 325 mm 88 mm Weight 13 5 kg Ambient conditions Temperature range 0 C 40 C Relative humidity 50 non condensing Technical specifications 34 DPX 620III 6 Ch dimmer...

Page 35: ...ket the result of an incorrect connection may be a destroyed DMX controller a short circuit or just a not working light show The unit offers a 3 pin XLR socket for DMX output and a 3 pin XLR plug for...

Page 36: ...and markings on the packaging This product is subject to the European Waste Electrical and Electronic Equipment Directive WEEE in its currently valid version Do not dispose with your normal household...

Page 37: ...Notes DPX 620III 6 Ch 37 dimmer pack...