background image

4

The receiving range between Control Unit and Receiver is approximately 30 metres indoors, 
however many factors can affect the RF transmission and shorten the operating distance, e.g. 
shielding by thick walls, foil back plasterboard, metal objects such as filing cabinets, general 
RF interference, etc.

The range is generally large enough for most household applications, but it is advisable to test 
the RF transmission from the intended control unit location to the receiver location before fixing 
the control unit to the wall. 

To check the RF reception, follow the following steps:
1.  Press the   button on the Control Centre until the set temperature is higher than room 

temperature by a few degrees.

2.  Wait for a few seconds. The Burner on (heat call) indicator should appear on the bottom left of 

the LCD on the Control Unit.

3. Check the green LED on the receiver unit – it should be lit.
4. Press the   button to adjust the set temperature to be lower than room temperature.
5.  Wait for a few seconds, and the Burner on (heat call) indicator should disappear and the green 

LED should switch off.

6.  If at step 3 the green LED is not illuminated, press the The 

Reset

 on the control unit and try to 

place the control unit closer to the receiver.

7. Repeat steps 1-5.

If you are unable to get a stable RF connection between the Receiver and Control Unit, check that 
the Receiver is both switched on and has a mains supply (orange LED lit). If this isn’t the problem 
you can also alter the RF address code by following the “RF Address Code Setting” section of 
this manual, and should then repeat steps 1 to 5 (note that the 

Reset

 button on the Control Unit 

should be pressed after altering the address code).

User Instructions

User Control Function Summary

Key

Function

Increase temperature setting

Decrease temperature setting

 

Changes unit to comfort mode

 

Changes unit to economy mode

D

Set the day of the week

H

Set the hour of day

M

Set the minute

Set

Key for Program settings

Select

Key for Program settings

ON/OFF

Short Press: Power off mode 
Long press for 3 seconds: user setting selection for Offset

Reset

To reset the thermostat

Summary of Contents for TPSRF51

Page 1: ...tside wall above a radiator or in a location where it may be subjected to direct sunlight To ensure trouble free receiving of the Radio Frequency RF signal always ensure that the programmable thermostat is mounted away from any possible sources of interference such as radio TV sets computer etc locating the TPSRF51 in enclosed areas such as cellars and basements is not recommended position your th...

Page 2: ... the rear of the Receiver Receiver Wiring Terminals Terminal Name Function N Neutral input 230VAC 50Hz L Live input 230VAC 50Hz 1 COM Switch common terminal 2 NO Normal open Volt Free Contact 3 NC Normal close Volt Free Contact Direct Control Boiler RECEIVER N 0 COM L N N L BOILER Live Feed N E L N E MAINS FEED Brown Green Yellow Blue Brown Blue Notes Receiver unit should have a permanent 230V AC ...

Page 3: ...F transmissions from a Control Unit that has the same RF address code setting Disconnect any AC power to the Receiver and remove the batteries from the Control Unit before attempting any adjustment of the RF Address Code switch and jumpers If you are not sure how to carry out this operation correctly consult either with a qualified electrician or heating engineer To adjust the RF address code of t...

Page 4: ...emperature 5 Wait for a few seconds and the Burner on heat call indicator should disappear and the green LED should switch off 6 If at step 3 the green LED is not illuminated press the The Reset on the control unit and try to place the control unit closer to the receiver 7 Repeat steps 1 5 If you are unable to get a stable RF connection between the Receiver and Control Unit check that the Receiver...

Page 5: ...nnel is turned on for heating 6 Low batt indicator Indicates battery replacement is required 7 Auto Comf Econ Off mode indicator Indicates current mode Auto Comfort Economy Off 8 Set icon Indicates unit in setting mode 9 Program icon Indicates unit in programming mode Both SET and PROG are shown at the same time as SET PROG 10 Snowflake icon Indicates when unit is in OFF mode Initial Power Up Afte...

Page 6: ...ues Clock 12 00AM Day of week Monday Mode AUTO Program 5 2 days Default Program Setpoint Temperatures Program Weekday Mon to Fri Weekend Sat to Sun 1 Time 06 30 Time 08 00 Temp 21 C Temp 21 C 2 Time 08 00 Time 10 00 Temp 18 C Temp 21 C 3 Time 12 00 Time 12 00 Temp 21 C Temp 21 C 4 Time 14 00 Time 14 00 Temp 18 C Temp 21 C 5 Time 18 00 Time 18 00 Temp 21 C Temp 21 C 6 Time 22 30 Time 23 00 Temp 16 ...

Page 7: ... AUTO COMF ECON or OFF The default mode is AUTO 1 COMF mode Press anytime in other modes to enter COMF mode The screen displays and the setting flashes for 5 seconds When the temperature flashes the setting can be changed default 21 C by using ᴧ or ᴠ in increments of 0 5 C Press and hold the buttons the setting will change continuously in increments of 1 0 C Wait 5 seconds to confirm the temperatu...

Page 8: ...d with the Minutes flashing press or to change Press Select to set the minute Press Set to return to the home screen and store the setting 5 Program 1 will display with the temperature flashing press or to change Press Select to set the temperature Press Set to return to the home screen and store the setting 6 Program 1 and its temperature is set Program 2 and the Hour will flash for 10 seconds to...

Page 9: ...oint Temp 16 C If you change program 5 start time from 6pm to 7am The new program setting is as below using the temperature setting of the last conflicting programme i e uses 19 C in our example New Program 1 Time 06 30am Setpoint Temp 21 C 2 Time 7 00am Setpoint Temp 18 C 3 Time 7 00am Setpoint Temp 23 C 4 Time 7 00am Setpoint Temp 21 C 5 Time 7 00am Setpoint Temp 19 C 6 Time 10 30pm Setpoint Tem...

Page 10: ...attery voltage below 2 4V the low battery indicator will be displayed on LCD When low battery occurs the backlight will not illuminate Battery Cut off Handling When the batteries reach cut off voltage 2 1V the LCD will turn off After battery cut off occurs the thermostat will enter a cut off state until new batteries have been fitted BOSS is a registered trademark of the Travis Perkins Group Regis...