Instruction Manual

 

TPSRF51 (957707) - BOSS

TM

 Universal RF Programmable Room Thermostat (Wireless)

(7 day, 5/2 day and 24 hour programme options)

Thank you for purchasing this product. If installing for someone else, please ensure that the 
instructions are handed to the householder.

Please read this manual prior to installation or use.

Always isolate the mains power supply before removing the unit from the backplate.

Do not mix old and new batteries. Do not use rechargeable batteries.

Please leave these instructions with the end user where they should be kept in a safe place for 
future reference

Installation

TPSRF51 Control Unit is easily installed using the backplate supplied with the unit – this is purely 
for mounting purposes, as no wiring is needed for the Control Unit. The backplate can be mounted 
directly to the wall surface without using a back box.

The ideal position to locate the TPSRF51 RF Programmable Room Thermostat is about 1.5m above 
floor level, in a location where the thermostat is accessible, reasonably lit and free from extremes 
of temperature and draughts. Do not mount the thermostat on an outside wall, above a radiator or 
in a location where it may be subjected to direct sunlight.

To ensure trouble free receiving of the Radio Frequency (RF) signal, always ensure that the 
programmable thermostat is mounted away from any possible sources of interference (such 
as radio, TV sets, computer, etc.), locating the TPSRF51 in enclosed areas such as cellars and 
basements is not recommended, position your thermostat where the temperature will be 
representative of that in the zone being controlled.

Connecting the TPSRF51 RF Receiver

NOTE :  All electrical installation work should be carried out by a suitably qualified Electrician or other 

competent person.

If you are not sure how to install this digital thermostat consult either with a qualified electrician, 
heating engineer or your boiler/heating system supplier for advice on how to continue.

The TPSRF51 Receiver should be mounted in a suitable location that is both accessible for the 
connection of mains and control wiring, and allows good reception of the RF signal. The Receiver 
needs a 230V AC mains supply to operate, and this should be fused appropriately (13A max.) The 
Receiver should be mounted in a location where it will not come into contact with water, moisture 
or condensation.
The Receiver On/Off switch is accessible from the front face of the Receiver.

Summary of Contents for TPSRF51

Page 1: ...tside wall above a radiator or in a location where it may be subjected to direct sunlight To ensure trouble free receiving of the Radio Frequency RF signal always ensure that the programmable thermostat is mounted away from any possible sources of interference such as radio TV sets computer etc locating the TPSRF51 in enclosed areas such as cellars and basements is not recommended position your th...

Page 2: ... the rear of the Receiver Receiver Wiring Terminals Terminal Name Function N Neutral input 230VAC 50Hz L Live input 230VAC 50Hz 1 COM Switch common terminal 2 NO Normal open Volt Free Contact 3 NC Normal close Volt Free Contact Direct Control Boiler RECEIVER N 0 COM L N N L BOILER Live Feed N E L N E MAINS FEED Brown Green Yellow Blue Brown Blue Notes Receiver unit should have a permanent 230V AC ...

Page 3: ...F transmissions from a Control Unit that has the same RF address code setting Disconnect any AC power to the Receiver and remove the batteries from the Control Unit before attempting any adjustment of the RF Address Code switch and jumpers If you are not sure how to carry out this operation correctly consult either with a qualified electrician or heating engineer To adjust the RF address code of t...

Page 4: ...emperature 5 Wait for a few seconds and the Burner on heat call indicator should disappear and the green LED should switch off 6 If at step 3 the green LED is not illuminated press the The Reset on the control unit and try to place the control unit closer to the receiver 7 Repeat steps 1 5 If you are unable to get a stable RF connection between the Receiver and Control Unit check that the Receiver...

Page 5: ...nnel is turned on for heating 6 Low batt indicator Indicates battery replacement is required 7 Auto Comf Econ Off mode indicator Indicates current mode Auto Comfort Economy Off 8 Set icon Indicates unit in setting mode 9 Program icon Indicates unit in programming mode Both SET and PROG are shown at the same time as SET PROG 10 Snowflake icon Indicates when unit is in OFF mode Initial Power Up Afte...

Page 6: ...ues Clock 12 00AM Day of week Monday Mode AUTO Program 5 2 days Default Program Setpoint Temperatures Program Weekday Mon to Fri Weekend Sat to Sun 1 Time 06 30 Time 08 00 Temp 21 C Temp 21 C 2 Time 08 00 Time 10 00 Temp 18 C Temp 21 C 3 Time 12 00 Time 12 00 Temp 21 C Temp 21 C 4 Time 14 00 Time 14 00 Temp 18 C Temp 21 C 5 Time 18 00 Time 18 00 Temp 21 C Temp 21 C 6 Time 22 30 Time 23 00 Temp 16 ...

Page 7: ... AUTO COMF ECON or OFF The default mode is AUTO 1 COMF mode Press anytime in other modes to enter COMF mode The screen displays and the setting flashes for 5 seconds When the temperature flashes the setting can be changed default 21 C by using ᴧ or ᴠ in increments of 0 5 C Press and hold the buttons the setting will change continuously in increments of 1 0 C Wait 5 seconds to confirm the temperatu...

Page 8: ...d with the Minutes flashing press or to change Press Select to set the minute Press Set to return to the home screen and store the setting 5 Program 1 will display with the temperature flashing press or to change Press Select to set the temperature Press Set to return to the home screen and store the setting 6 Program 1 and its temperature is set Program 2 and the Hour will flash for 10 seconds to...

Page 9: ...oint Temp 16 C If you change program 5 start time from 6pm to 7am The new program setting is as below using the temperature setting of the last conflicting programme i e uses 19 C in our example New Program 1 Time 06 30am Setpoint Temp 21 C 2 Time 7 00am Setpoint Temp 18 C 3 Time 7 00am Setpoint Temp 23 C 4 Time 7 00am Setpoint Temp 21 C 5 Time 7 00am Setpoint Temp 19 C 6 Time 10 30pm Setpoint Tem...

Page 10: ...attery voltage below 2 4V the low battery indicator will be displayed on LCD When low battery occurs the backlight will not illuminate Battery Cut off Handling When the batteries reach cut off voltage 2 1V the LCD will turn off After battery cut off occurs the thermostat will enter a cut off state until new batteries have been fitted BOSS is a registered trademark of the Travis Perkins Group Regis...