4. TROUBLESHOOTING
PROBLEM
CAUSE
SOLUTION
Pump will NOT
start
Low air supply
Check air supply
Pump stalls under
load
Low air pressure
Check air supply
Pump operates but
cylinder doesn’t
move
Low oil level
Check oil level
Coupling not fully
connected
Check couplings
Overloaded at
maximum pressure
Check system pressure
External leak
Check hoses, couplers and
connectors
Internal leak
Contact a Boss Hydraulics
Authorised Service Centre
Suction blocked
Contact a Boss Hydraulics
Authorised Service Centre
Breather blocked
Contact a Boss Hydraulics
Authorised Service Centre
Pump fails to build
full pressure
Low air pressure
Check air pressure
External leak
Check hoses, couplers and
connectors
Internal leak
Contact a Boss Hydraulics
Authorised Service Centre
4. MAINTENANCE
• Clean after use with warm soapy water being careful not to introduce the
water to the oil in the reservoir through the filler breather.
• When not in use pumps should be stored in a cool dry area free from dust.
•
The air filter should be cleaned
and drained of water frequently both prior
to use and during long periods of use.
•
Change oil after 250 hours use or every 2 years, more frequently in dusty
environments.
• Servicing should be carried
out by a qualified hydraulic technician.