- 9 -
BOSS ARC 140
、
160 Operating Manual
2.02 Specifications
MODEL
BOSS ARC 140
BOSS ARC 160
Input voltage and frequency and phases
220/240V 50/60Hz 1ph
220/240V 50/60Hz 1ph
TIG
4.3KVA
4.8KVA
KVA @ max output
STICK
6.0KVA
7.4kVA
Max current
140A
160A
Output current range
10~140A
10~160A
Open circuit voltage
56/61V
56/61V
Duty cycle at 40
℃
60%
60%
Weight
9.5kg
12kg
Dimensions (mm)
370
×
150
×
245
420
×
160
×
265
Table 3
2.03 Duty cycle
The duty cycle of a welding power source is the percentage of a ten (10) minute period that it can be
operated at a given output without causing overheating and damage to the unit. If the welding amperes
decrease, the duty cycle increases. If the welding amperes are increased beyond the rated output, the duty
cycle will decrease.
WARNING
: Exceeding the duty cycle ratings will cause the thermal overload
protection circuit to become energized and shut down the output until has cooled
to normal operating temperature
Continually exceeding the duty cycle ratings
can cause damage to the welding power source.
NOTICE
:
Due to variations that can occur in manufacture products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities and
ratings in use and operation will depend upon correct installation, use, applications, maintenance and service.