background image

12

EN

fig. 3

Flanged connections

DN 65 - DN 80 - DN 100 

19mm

Summary of Contents for 35501216

Page 1: ...SSURE REGULATOR 356 P1 max 500 mbar DN15 DN 20 DN 25 DN 32 DN 40 DN 50 DN 65 DN 80 DN 100 EN EC approval according to EN 88 1 compliant with Regulation EU 2016 426 CE 51CL4012 ED01 MADE IN ITALY II 2G...

Page 2: ...2 EN INDEX pag English 3 Drawings 10 Dimensions table 1 13 Regulation spring data table 3 14 Diagram 15...

Page 3: ...2 KEY OF SYMBOLS ATTENTION Attention is drawn to the technical details intended for qualified staff DANGER In the event of inobservance this may cause damage totangiblegoods topeopleand orpets DANGER...

Page 4: ...downstream of the regulator IMPORTANT install manual gas closing devices e g ball valves upstream and downstream of the regulator to protect it from any pipe leak test If the device is threaded make s...

Page 5: ...imum torque has been achieved uniformly Common procedures threaded and flanged devices The regulator is normally positioned before the utility Primarily evaluate the possibility of installing the regu...

Page 6: ...ns provided in this document it does not pose a source of specific hazards in particular under normal operating conditions the regulator emits a flammable substance into the atmosphere ONLY if both th...

Page 7: ...E Before starting the system make sure that the spring supplied with the regulator is suitable for the desired adjustment pressure The outlet pressure P2 unless specifically requested is factory set w...

Page 8: ...ary Make sure the sealing O Ring 18 of the bottom cover 16 is inside the relevant groove before putting it back on Reassemble the bottom cover 16 and secure it in its original position being very care...

Page 9: ...hts of the warranty or compensation for damage The warranty also excludes maintenance work other manufacturers s assembling units making changes to the device and natural wear 8 0 RATING PLATE DATA Th...

Page 10: ...10 EN fig 1 Threaded connections in line DN 15 DN 20 DN 25...

Page 11: ...11 EN fig 2 Threaded connections in line DN 32 DN 40 DN 50...

Page 12: ...12 EN fig 3 Flanged connections DN 65 DN 80 DN 100 19mm...

Page 13: ...21 Filter element 22 Top disk for membrane 23 Top cover clamping screws 24 Bottom disk for membrane 25 Membrane disc fixing nut 26 Spring washer Table 2 Screw M5 M6 Max torque N m Galvanised 6 10 Sta...

Page 14: ...3 23 MO 0850 2 2x29x140x18 20 36 MO 0970 2 5x29x155x16 33 58 MO 1000 3 2x29x123x15 5 55 100 MO 1370 3 5x29x125x14 90 190 MO 1070 4x66 5x155x16 DN 65 DN 80 7 18 MO 1100 4 5x70x200x15 5 13 27 MO 1200 5x...

Page 15: ...15 EN Capacity diagram Diagram calculated with P1 50 mbar and regulator set out of service dv density relative to the air 1 methane 2 air 3 town gas 4 lpg...

Page 16: ...he right to any technical and construction changes Registered Office Travis Perkins PLC Lodge Way House Lodge Way Harlestone Road Northampton NN5 7UG Telephone Number 0116 245 5500 www bssindustrial c...

Reviews: