TUFLOCK
®
DIY Solar Kit
- Installation Manual
8
PLUMB THE SYSTEM TO THE PUMP HOUSE
INDEPENDENT / SEPARATE SUCTION SYSTEM
The pool water is pumped directly from the pool to the solar collector and then back. This
configuration requires solar provisions to have been pre-installed. It is simple to install and does
not interrupt the filtration system. This type of plumbing allows the Solar System to operate
independent of the filtration system.
TO INSTALL
Identify and confirm the solar Supply and Return lines, even if they are labelled. This can be
achieved by removing the caps (if there are any) and yelling down the pipes or by pouring water
down the line. The Suction line should join at the swimming pool to two suction points, typically
deep on the wall of the pool. The Return line is typically a single return outlet, usually higher on
the pool wall than the suction lines. Plumb as per the diagram above. Ensure all pipework is dry
and clean before attempting to glue.
REQUIRES
•
1 x AS2, AS2_2S Digital Solar Controller or similar
•
1 x Check Valve (also known as a Non-Return or One-Way Valve)
•
1 x Solar Pump (that can deliver 3-4 litres per minute per m² of collector)