Important:

The fuel tank is located directly

behind the side plate. Remove the fuel tank
or place a steel plate between the fuel tank
and side plate to prevent damaging the tank.

3.

Secure the hydraulic manifold mounting bracket
to the machine using 3 bolts (3/8 x 1 inch), 3 flat
washers, and 3 nylon locknuts (

Figure 6

).

g303474

Figure 6

1.

Nylon locknut (3/8 inch)

3.

Bolt (3/8 x 1 inch)

2.

Flat washer (3/8 inch)

4.

Hydraulic manifold
mounting bracket

4.

Mount the hydraulic manifold assembly to the
mounting bracket using 2 bolts (3/8 x 3/4 inch)
as shown in

Figure 7

.

g303475

Figure 7

1.

Hydraulic manifold
assembly

2.

Bolt (3/8 x 3/4 inch)

5.

Route the BOSS hydraulic-manifold wire
harness over the fuel tank and connect it to the
auxiliary-power connector on the wire harness
of the machine (

Figure 8

).

g036938

Figure 8

1.

Controller connector

2.

Auxiliary-power connector

6.

Connect the BOSS hydraulic-manifold wire
harness to the controller connector (

Figure 8

).

7.

Secure the BOSS hydraulic-manifold wire
harness to the wire harness of the machine with
cable ties.

3

 

Summary of Contents for MSC13950

Page 1: ...the Machine 1 Park the machine on a level surface shut off the engine wait for all moving parts to stop engage the parking brake and remove the key 2 Support the machine on jack stands 3 Release the c...

Page 2: ...sole using 4 hex head bolts 1 4 inch and 4 nylon locknuts 1 4 inch 5 Attach the strain relief plug to the controller cable approximately 7 cm 3 inches from the controller Figure 4 g036935 Figure 4 1 S...

Page 3: ...mounting bracket 4 Mount the hydraulic manifold assembly to the mounting bracket using 2 bolts 3 8 x 3 4 inch as shown in Figure 7 g303475 Figure 7 1 Hydraulic manifold assembly 2 Bolt 3 8 x 3 4 inch...

Page 4: ...freely 4 Attach the bulkhead bracket to the A frame using 2 hex head bolts 3 8 inch and 2 nylon locknuts 3 8 inch as shown in Figure 10 and torque the bolts to 40 N m 30 ft lb Note Ensure that the qu...

Page 5: ...Install a 90 fitting and hose to the manifold 6 Place a drain pan under the manifold block of the left hydrostatic drive Figure 13 g303477 Figure 13 1 P port hose 4 Manifold block 2 Filter hose 5 Inn...

Page 6: ...t was removed 3 Start the machine refer to your Grandstand Multi Force Operator s Manual 4 Use the controls to move the hydraulics in all directions to cycle the hydraulic fluid 5 With the hydraulic c...

Page 7: ...n and all that the hydraulic connections and fittings are tight before applying pressure to the hydraulic system Keep your body and hands away from pinhole leaks or nozzles that eject high pressure hy...

Page 8: ...Schematics g037075 Electrical Schematic Rev 0 8...

Page 9: ...R valve 6 Angle right coil red 2 Float coil blue 7 Raise coil orange wire 3 Lower coil white 8 ANGLE RIGHT LEFT valve 4 Float coil red and black 9 Pressure relief valve 5 Angle left coil green Hydraul...

Page 10: ...Notes...

Page 11: ...Notes...

Page 12: ......

Reviews: