background image

 

Page | 5 

 

 
 
EXTENSION CORDS

 

Use  only  3-wire  extension  cords  that  have  3-prong 
grounding  plugs  and  3-pole  receptacles  that  accept  the 
tool's  plug.  When  using  a  power  tool  at  a  considerable 
distance  from  the  power  source,  use  an  extension  cord 
heavy enough to carry the current that the tool will draw. An 
undersized extension cord  will cause a drop  in line voltage, 
resulting  in  a  loss  of  power  and  causing  the  motor  to 
overheat.  Use  the  chart  provided  below  to  determine  the 
minimum  wire  size  required  in  an  extension  cord.  Only 
round  jacketed  cords  listed  by  Underwriter's  Laboratories 
(UL) should be used. 

 

**Ampere rating  (on tool faceplate)

 

0-2.0  

2.1-3.4  

3.5-5.0  

5.1-7.0  

7.1-12.0   12.1-16.0

 

 

Cord

 

Length

 

 

Wire Size 

 

 (A.W.G.)

 

 

25'

 

16

 

16

 

16

 

16

 

14

 

14

 

50'

 

16

 

16

 

16

 

14

 

14

 

12

 

100'

 

16

 

16

 

14

 

12

 

10

 

 

**Used on 12 gauge - 20 amp circuit.

 

NOTE: 

AWG = American Wire Gauge

 

ELECTRICAL CONNECTION

 

This  tool  is  powered  by  a  precision  built  electric  motor.  It 
should be connected  to a 

power supply that is 115 volts,

 

60 

Hz,

 AC only (normal household current). 

Do not operate 

this  tool  on  direct  current  (DC). A substantial  voltage  drop 
will  cause  a  loss  of  power  and  the  motor  will  overheat.  If 
the product  does not operate when plugged  into an outlet, 
double check the power supply.

 

 

SPEED AND WIRING

 

The  speed  is  not  constant  and  decreases  under  a  load 
or with lower voltage. For voltage, the wiring in a shop 
is as important as the motor’s horsepower rating. A line 
intended only for lights cannot properly carry a power 
tool motor. Wire that is heavy enough for a short 
distance will be too light for a greater distance. A line 
that can support one power tool may not be able to 
support two or three tools. 

 

 
When working with the tool outdoors, use an extension cord 
that  is  designed  for  outside  use.  This  is  indicated  by  the 
letters "WA"  on the cord's  jacket.

 

Before  using  an  extension  cord,  inspect  it  for  loose  or 
exposed wires and cut or worn insulation.

 

 

 

WARNING:

 

 

Keep the  extension  cord  clear of  the  working  area. 
Position the cord so that it will not get caught on lumber, 
tools  or other obstructions  while you are working  with  a 
power tool. Failure to do so can result in serious personal 
injury.

 

 

 

WARNING:

 

 

Check  extension  cords  before  each  use. If  damaged 
replace immediately. Never use tool with a damaged cord 
since touching the damaged area could cause electrical 
shock resulting in serious injury.

 

GROUNDING INSTRUCTIONS 

In  the  event  of  a  malfunction  or  breakdown,  grounding 
provides  a  path  of  least  resistance  for  electric  current  to 
reduce the risk of electric shock. This tool is equipped with 
an 

electric 

cord 

having 

an 

equipment-grounding  

conductor  and  a  grounding  plug.  The  plug  must  be 
plugged  into  a matching  outlet  that  is  properly  installed 
and  grounded  in accordance  with  all  local  codes  and 
ordinances. 

Do not  modify  the  plug  provided.  If it  will  not  fit  the  outlet, 
have  the  proper  outlet  installed  by  a  qualified  electrician. 
Improper 

connection 

of 

the 

equipment-grounding 

conductor  can  result  in  a  risk  of  electric  shock.  The 
conductor  with  insulation  having  an  outer  surface  that  is 
green  with  or  with-out  yellow stripes is  the  equipment-
grounding  conductor.  If  repair  or  replacement  of  the 
electric  cord  or  plug  is  necessary,  do  not  connect  the 
equipment-grounding  conductor to a live terminal. 

Check with a qualified electrician or service personnel if the 
grounding  instructions  are not completely  understood,  or if 
in doubt  as to whether the tool is properly grounded. 

Repair 

or 

replace a 

damaged 

or 

worn 

cord 

GROUNDING INSTRUCTIONS 

In  the  event  of  a  malfunction  or  breakdown,  grounding 
provides  a  path  of  least  resistance  for  electric  current  to 
reduce the risk of electric shock. This tool is equipped with 
an 

electric 

cord 

having 

an 

equipment-grounding 

conductor  and  a  grounding  plug.  The  plug  must  be 
plugged  into  a matching  outlet  that  is  properly  installed 
and  grounded  in accordance  with  all  local  codes  and 
ordinances.

 

Do not  modify  the  plug  provided.  If it  will  not  fit  the outlet, 
have  the  proper  outlet  installed  by  a  qualified  electrician. 
Improper 

connection 

of 

the 

equipment-grounding 

conductor  can  result  in  a  risk  of  electric  shock.  The 
conductor  with  insulation  having  an  outer  surface  that  is 
green  with  or  with-out  yellow stripes is  the  equipment-
grounding  conductor.  If  repair  or  replacement  of  the 
electric  cord  or  plug  is  necessary,  do  not  connect  the 
equipment-grounding conductor to a live terminal.

 

Check with a qualified electrician or service personnel if the 
grounding instructions  are not completely  understood,  or if 
in doubt  as to whether the tool is properly grounded.

 

Repair  or  replace a  damaged  or  worn  cord  immediately. 
This tool  is intended  for use on a circuit  that  has an outlet

 

like  the  one  shown  below. Ensure that the outlet has a 
grounding pin. 

 

 

ELECTRICAL CONNECTION

 

ELECTRICAL SAFETY 

 

Summary of Contents for ED8T20

Page 1: ...OPERATING INSTRUCTIONS Purchase Date___________________ Serial No ______________________ Dealer________________________________________________________ Boss Industrial Inc 1864 High Grove Lane Unit 11...

Page 2: ......

Page 3: ...ral Safety 7 Work Area 8 Operation of the Log Splitter 8 Maintenance Safety 9 Hydraulic Safety 10 Fire Prevention 10 Assembly Instructions 11 12 Pre Operation Instructions 12 Operating Instructions 13...

Page 4: ...nt safety information may result in serious injury or death INTENDED USE NEVER use this log splitter for any purpose other than splitting wood It is designed for this use only Any other use can cause...

Page 5: ...Page 2...

Page 6: ...To reduce the risk of injury user must read and understand operator s manual before using this product Eye Face Ear Protection Always wear safety goggles or safety glasses with side shields earplugs a...

Page 7: ...uct to your nearest AUTHORIZED SERVICE CENTER for repair When servicing use only identical replacement parts WARNING To avoid serious personal injury do not attempt to use this product until you read...

Page 8: ...d cause electrical shock resulting in serious injury GROUNDING INSTRUCTIONS In the event of a malfunction or breakdown grounding provides a path of least resistance for electric current to reduce the...

Page 9: ...egs log holder 4 Machine body 5 Control handle 6 115v motor 7 Motor control box 8 On Off switch 9 Electrical cable with plug 10 Oil reservoir 11 Oil drain bolt with dipstick 12 Vent plug 13 Towing han...

Page 10: ...rical shock by preventing body contact with grounded surfaces For example pipes radiators ranges refrigerator enclosures KEEP guards in place and in good working order USE the proper extension cord Ma...

Page 11: ...s or pieces of wood on the tool while it is in operation ONLY operate your log splitter in daylight or under good artificial light ALWAYS keep the work area clean Remove split wood around your log spl...

Page 12: ...even if you are leaving the log splitter for a short period of time NEVER operate your log splitter when it is in poor mechanical condition or in need of repair Periodically check that all nuts bolts...

Page 13: ...r medical treatment is not administered immediately ALWAYS be sure to relieve all pressure by shutting off the motor and moving the control handle back to stop position NEVER remove the vent plug from...

Page 14: ...handle lever into handle bracket and attach safety shield before operation see FIGURE 3 WARNING If any parts are damaged or missing do not operate this tool until the missing parts are replaced Failu...

Page 15: ...ve accumulated during shipping Operate the log splitter for several cycles to repel the air Do not move the splitter while the vent plug is loosened as the hydraulic fluid could spill out NOTE Failure...

Page 16: ...nage If you experienced problems splitting especially hard wood do not continue to push on the control handle for more than 3 seconds Release the control handle at once to avoid damage If the motor st...

Page 17: ...heat up and could damage the tool This machine can fit in most vehicles for transportation Ensure that the splitter is properly secured before the vehicle is in motion Ensure vent plug is tightened an...

Page 18: ...cient amount of high grade lubricant for the life of the unit under normal operating conditions Therefore no further lubrication is required on the bearings REPLACING HYDRAULIC OIL See FIGURES 6 7 8 9...

Page 19: ...Page 16 FIGURE 6 Drain Oil from Reservoir FIGURE 7 Note Acceptable Oil Fill Level FIGURE 8 Place Log Splitter In Vertical Position FIGURE 9 Remove the safety shield and refill Oil to Desired Level...

Page 20: ...harpening The Wedge in the Maintenance section Locate leak s Contact the dealer Contact the dealer Log ram jerks vibrates or does not move Unit is not placed on level ground Lack of hydraulic oil Exce...

Page 21: ...plitting force Extending 8 ton Retracting 7 ton Max splitting length 20 5 in Max splitting diameter 10 5 in Hydraulic pressure 3400 PSI Cylinder bore 2 5 in Cycle time Extending 9 sec Retracting 13 se...

Page 22: ...Page 19 EXPLODED DIAGRAM PARTS LIST...

Page 23: ...r Seal Washer M16 1 2 22 730 564 O Seal Ring 20 1 9 2 23 520 767 Hydraulic Valve 1 24 710 991 Inner Hex Head Bolt M8 55 2 25 730 624 O Seal Ring 18 1 9 2 26 750 158 Copper Seal Washer M14 1 2 27 710 8...

Page 24: ...Plate 1 68 750 834 Spring Washer M8 2 3 1 69 520 682 Control Handle Connecting Shaft 12 5 56 1 70 520 002 Control Handle Lever 12 5 116 1 71 350 144 Hydraulic System Shield Near Side 1 72 350 295 Hyd...

Page 25: ...r to any product that has been altered or modified The warranty does not extend to repairs made necessary by normal wear or by the use of parts or accessories which are either incompatible with the BO...

Page 26: ...Page 23 1 Log Splitter 1 Safety Shield 1 Control Lever 1 Operator s Manual 1 Hex Wrench PACKING LIST...

Page 27: ...Page 24...

Page 28: ...Page 25 Boss Industrial Inc 1864 High Grove Lane Unit 116 Naperville IL 60540 USA Phone 800 780 BOSS 2677 Fax 331 472 2976 www boss industrial com...