background image

Bosean Electronic Technology Co.,Ltd

www.bosean.com

- 1 -

Please read this manual carefully before using this product and keep it

for future reference, any deviation from the instructions may compromise the
safety, quality and performance of this instrument.

1. Introduction

BH-90E portable gas detector (hereinafter called detector) is a new type of
gas leak detector that adopts LSI technique and meets international smart
technology standards. With imported high quality semi-conductor sensor and
embedded microcontroller, it detects gas leakage with high sensitivity and
strong adaptive ability. Being waterproof, dustproof, explosion-proof, and
easy to use with high reliability, the detector is widely used in oil, coal,
municipal construction, chemical engineering, environmental protection,
metallurgy, refining, gas transmission and distribution, biochemistry,
agriculture, pharmaceutical industries.

Mail features and functions:

MCU control, low consumption

High resolution STN LCD

Housing made of high strength engineering plastics and compound
anti-slip rubber

Detection range (low alarm point, high alarm point) adjustable

Low battery alert, intrinsically safe design

3 alarm types: sound (mute mode also available), light and vibration

Gas calibration completed by the factory

Zero adjustment and data logging

2. Configuration & Structure

2.1 Configuration

Summary of Contents for BH-90E

Page 1: ...BH 90E Portable Gas Detector Operation Manual...

Page 2: ...rong adaptive ability Being waterproof dustproof explosion proof and easy to use with high reliability the detector is widely used in oil coal municipal construction chemical engineering environmental...

Page 3: ...eries display sensors chargers 3 Technical Specifications Target gas Combustible gas Range 0 10 000ppm mol mol Sampling method Natural diffusion Alarm point Default Low alarm 500ppm High alarm 2000ppm...

Page 4: ...f grade Exib IIB T3 Gb Sensor type Imported FIGARO sensor Sensor life 2 years Power supply Rechargeable lithium battery DC3 7V 1800mAH Charging time 6h 8h Continuous working hours No less than 8 hour...

Page 5: ...Bosean Electronic Technology Co Ltd www bosean com 4 see below 4 2 Self check After self check is done the device enters into detection interface see below 4 3 Detection interface 4 3 1 Overview...

Page 6: ...ion interface you may press to see all parameters 4 3 3 Alarm types Low alarm Red LED light LA on detection interface slow beeping vibration High alarm Red LED light HA on detection interface fast bee...

Page 7: ...m records review deletion purpose press on detection interface then it will enter the function menu see below 4 4 Function menu 4 4 1 Overview 4 4 2 Press or to choose a specific function then press t...

Page 8: ...ntact the seller to get the password first if it s needed When you see low battery alert or when the detector can t turn on because battery voltage is too low please charge the detector in time see be...

Page 9: ...rential high concentration gas detector may not work normally 5 4 The detector will only detect gas concentration from the detection interface So for example when you are on the function menu it will...

Page 10: ...es03 bosean com Possible fault Reasons Solution Unable to turn on the detector Battery voltage too low Charge in time Did not indicate 0 Sensor fluctuating Zero adjustment required Indication inaccura...

Page 11: ...Bosean Electronic Technology Co Ltd www bosean com 10...