Setup
Installation Options
Installation Options and Accessories
q
Mounting bracket (included)
w
DMSBRKT
pan-and-tilt bracket (optional; for indoors only)
e
WBPWR-50
pan-and-tilt bracket (optional; for outdoors)
q
w
e
Preparing the Input Cover
The input cover is designed for three different wiring scenarios (see above). To change the configuration of the input cover to support
your wiring scenario, cut along the perforation on the rubber conduit. Use one 1/2-inch to 1/2-inch threaded coupling and two 3/8-inch trade
size conduit fittings for 1/2-inch knockouts (see diagram below).
CAUTION:
Do not use the wide open wiring scenario when installing the input cover with a flexible conduit.
CAUTION:
To prevent water ingress, do not install the input cover facing upward.
Note:
It is the installer's responsibility to seal against water ingress into the Euroblock connector. Use outdoor or marine-grade silicone to
seal all wiring connections to ensure a tight seal.
Note:
Flexible conduits and couplings must be UL Listed, suitable for the application, and installed in accordance with the local authorities
having jurisdiction.
Single In
In and Out
Wide Open