background image

ControlCenter CV41 4-to-1 Converter

Use the ControlCenter CV41 4-to-1 converter to create a single home run connection back to a PowerShare PS602, PS404A, or 

PS604A amplifier when multiple CC-1 zone controllers are distributed throughout an installation. Connect each zone controller to the 

CV41 converter using CAT 5 cables with RJ-45 connectors, then run a single CAT 5 cable from the CV41 converter to the amplifier.
For more information, see the ControlCenter Zone Controllers Installation and Operation Guide.

CAT 5 cable

609 m (2000 ft) max

CAT 5 cable

7.6 m (25 ft) max

Adaptable Power Amplifier

LIMIT

SIGNAL

1

2

PowerShare

PS602

POWER

CAT 5 cable

609 m (2000 ft) max

CAT 5 cable

7.6 m (25 ft) max

Adaptable Power Amplifier

LIMIT

SIGNAL

1

2

3

4

PowerShare

PS604A

POWER

2.5 in

2.0 in

27 mm

1.1 in

Connect up to two CC-1 zone controllers to a PS602 amplifier, as shown below. If 

the two CC-1 zone controllers are ganged together first, then the CV41 converter 

is not required.

Connect up to four CC-1 zone controllers to a PS404A or PS604A amplifier, as 

shown below. You can also gang any combination of CC-1 zone controllers together 

first, then use the CV41 converter to create a single home run to the amplifier. All 

inputs on the CV41 converter are identical, so any input combination is acceptable.

CV41 Converter Diagram

Connecting the CV41 Converter

Top View

Bottom View

Left Side View

Right Side View