Fault diagnosis
2013-10-23 / DIS 113_58300000133444_ara_en_l
Repair Instructions Laundry Repair Instruction;T22
Page 13 of 35
4.1
Malfunctions
Fault
Possible cause
Troubleshooting
Washing too dry (drum empty detection)
Underload
► Also select timer programme
Error in the conductivity system
Humidity sensors have become coated
► For cleaning see operating instructions
Drying programme starts only briefly
Door lock function (open briefly)
► Advise customer
Switching contact does not switch
► Replace door switch
Cable break
► Replace cable
Motor not rotating
► Run motor test programme.
► Check motor capacitor / Replace
► Replacing the motor
Belt torn
► Replace belt.
Driving system
Drum does not turn
Rolling rollers damaged
► Replace rolling rollers of bearing shield.
Heat pump driers do not become very
warm
► Not a fault
Heating system
Appliance remains cold
Heat pump defective
► Run heat pump test programme (See circuit diagrams)