![Bosch WR8/11 G Series Installation And Operating Istructions Download Page 7](http://html.mh-extra.com/html/bosch/wr8-11-g-series/wr8-11-g-series_installation-and-operating-istructions_52931007.webp)
6 720 607 845 (2015/05)
Technical Characteristics and Dimensions | 7
2.8
Technical characteristics
Technical characteristics
Symbol
Units
WR8
WR11
Power and flow
Nominal useful power
Pn
kW
11,8
19,2
Minimum useful power
Pmin
kW
7
7
Useful power (adjustment range)
kW
7 - 11,8
7 - 19,2
Nominal thermal flow
Qn
kW
13,5
21,8
Minimum thermal flow
Qmin
kW
8,1
8,1
Gas data
1)
1) Hi 15 °C - 1013 mbar - dry: Natural gas 34.2 MJ/ m³ (9.5 kWh/ m³)
LPG: Butane 45.72 MJ/kg (12.7 kWh/kg) - Propane 46.44 MJ/kg (12.9 kWh/kg)
Supply pressure
LPG (butane/propane)
G30/G31
mbar
28-30/37
28-30/37
Consumption
LPG (butane/propane)
G30/G31
kg/h
1,0
1,6
Number of injectors
12
12
Water data
Maximum permissible pressure
2)
2) Considering the water dilution effect this value must not be exceeded
pw
bar
12
12
Temperature selector in fully clockwise position
Temperature rise
°C
50
50
Flow range
l/min
2 - 3,5
2 - 5,5
Minimum operating pressure
pwmin
bar
0,35
0,35
Minimum pressure for maximum flow
bar
0,55
0,65
Temperature selector in fully anti-clockwise position
Temperature rise
°C
25
25
Flow range
l/min
4 - 7
4 - 11
Minimum operating pressure
bar
0,45
0,45
Minimum pressure for maximum flow
bar
1,0
1,0
Combustion products
3)
3) For nominal calorific power.
Minimum low pressure
mbar
0,015
0,015
Flow
g/s
13
13
Temperature
°C
170
170
Table 5