6
72
0
610
576
GB
(02.
05)
46
App
e
nd
ix
9.5
O
per
a
ti
ona
l Fl
o
w d
iagr
a
m
s
9
.5.
1
D
o
m
es
ti
c
ho
t w
a
te
r
fun
c
ti
o
n
Fig.
6
6
Mains
switch
ON.
Green
light
ON.
Burner lights.
Red light ON.
Ignition spark for
5 seconds.
Fan runs to purge
gas from burner.
Repeats 5 times
before lock-out.
Hot
water
demand.
Pump ON
Diverter valve
operates.
Heat input
modulates to
maintain the
delivery
temperature.
Gas valve
closes.
Red light
OFF.
Fan runs for
upto 3 mins.
Pump runs
for 30secs.
Over temperature
shut-down if water
temperature is 8
°
C
above set value.
Burner remains OFF
until flow temperature
is below set value.
Gas valve shuts.
Pump remains ON.
Demand
ends.
Yes
No
** NOTE:
The appliance controls can be set to one of
2 modes of operation.
1.
“
Comfort
“ mode -
Full pre-heat
2.
“
ECO
“ mode -
a) Operates as an instantaneous combination
boiler.
b) Demand Detection: a short demand (less
than 5 seconds) switches the control to
“Comfort“ mode for 5 mins. Mini pre-heat.
The Factory setting is “
Comfort
“ mode.
Fan to
start speed.
Gas valve opens.
Pre-heat
mode.**
Ignition sequence
Pre-heat
mode.**
Burner shut-down if
primary temperature
exceeds 94
°
C remains
OFF until 78
°
C
Pump ON
Diverter valve
operates.
Fan to
start speed.
Gas valve opens.
Pre-heat satisfied.
Ignition sequence
Burner lights.
Red light ON.
Ignition
spark
5 secs
.
6 720 610 576 - 24.1O