CLEARANCES

Minimum clearances in millimetres.
Your installer will have provided adequate space around the

appliance for safety and servicing. Do not restrict this space by the
addition of cupboards, shelves etc. close to the appliance. 

ROOM THERMOSTAT

A room thermostat may be fitted for control of the central heat-

ing temperature. It will be located in one room of the home. The
method of setting a room thermostat varies with the type and manu-
facture. Refer to the instructions supplied with the room thermostat.

THERMOSTATIC RADIATOR VALVES

If thermostatic radiator valves are fitted to the system then they

must conform to the requirements of BS2767. The radiator located in
the room where the room thermostat is sited must be controlled by a
thermostatic radiator valve.

SHOWERS, BIDETS, TAPS AND MIXING
VALVES

Standard hot and cold taps and mixing valves used with the

appliance must be suitable for operating at mains pressure.
Thermostatically controlled shower valves will guard against the flow
of water at too high a temperature.

If using a pressure equalising valve, set the Domestic Hot Water

temperature control knob to the ‘MAX’ position.

Hot and cold mains fed water can be supplied direct to an over-

rim flushing bidet subject to local water company requirements.

With all mains fed systems the flow of water from the individ-

ual taps will vary with the number of outlets operated simultaneous-
ly and the cold water mains supply pressure to the property. Flow bal-
ancing using ‘Ball-o-Fix’ type valves is recommended to avoid an
excessive reduction in flow to individual outlets.

For further information contact The Worcester Technical

Helpline. 08705 266241

HOT AND COLD FLOW

The flow of water demanded from both hot and cold service out-

lets is dependent upon mains supply, it may not be possible in some
installations to operate all outlets simultaneously.

WATER MAINS FAILURE

It is important to note that in the event of a mains water supply

failure, no tap water will be available until the mains supply is
restored. The appliance can still be used for heating provided that the
system is of the sealed system type. Open vent central heating sys-
tems should be turned off until the supply is restored.

USE IN HARD WATER AREAS

Normally there is no need for scale protection. However, in areas

of exceptionally hard water supply it is recommended that an In-Line
scale inhibitor be fitted.

Installation should be strictly in accordance with the require-

ments of the local Water Company. An isolating valve to facilitate
servicing should be incorporated.

24,28CDi RSF

35CDi 

II

24CDi OF

24CDiBF

Left-hand side

10

10

10

10

Right-hand side

10               10

10

10

In Front

600

600

600

600

Above

180             180

300

100

Below

200             200

200

200

Summary of Contents for Worcester 24CDi

Page 1: ...Fanned Flued RSF 47 311 30 47 311 31 24CDi Balanced Flued BF 47 311 29 24CDi Open Flued OF 47 311 32 47 311 33 28CDi Fanned Flue RSF 47 311 34 47 311 35 35CDi II Fanned Flue RSF 47 311 58 47 311 59 Vote for your Installer of the year at www worcester bosch co uk Worcester supports the Benchmark code of practice ...

Page 2: ...our new Worcester CDi appliance offers you the very best of every thing quality efficiency economical running costs proven reliability and value for money What s more you also have the assurance of our no nonsense 1 year parts and labour guarantee And to keep your boiler operating at peak condition and efficiency an optional maintenance scheme is available from Worcester Contact our Service Contra...

Page 3: ...mmissioning and servicing of domestic cen tral heating boilers and system equipment A checklist can be found in the back of every installation manual This is a vital document that needs to be completed by the installer at the time of installation It confirms that the boiler has been installed and commissioned according to the manufacturers instructions In Eire the declaration found in IS 813 must ...

Page 4: ... to maximum The appliance will operate as necessary to main tain the temperature of the radiators at the level set by the adjustment of the Heating Temperature Control Knob See Fig 2 If the system no longer requires output to maintain the desired room tempera ture the burner will extin guish The pump will contin ue to run for a short period to dissipate the residual heat from the appliance and the...

Page 5: ...engineer if there is a permanent significant drop in pressure indi cated on the gauge If the system loses pressure it should be re pressurised as instructed by the installer N B Maximum operating pressure 2 5 bar Re pressurising The System See Fig 1a If in doubt leave this procedure to your installer Remove the bottom panel to gain access to the fill ing loop assembly Insert the bayonet end of the...

Page 6: ... requirements With all mains fed systems the flow of water from the individ ual taps will vary with the number of outlets operated simultaneous ly and the cold water mains supply pressure to the property Flow bal ancing using Ball o Fix type valves is recommended to avoid an excessive reduction in flow to individual outlets For further information contact The Worcester Technical Helpline 08705 266...

Page 7: ... use the compartment for storage purposes unless it conforms to the requirements of BS 6798 1987 Section 6 It is essential that the airing space is separat ed from the boiler space by a perforated non combustible partition as described in BS 6798 1987 CIRCULATING PUMP This may be fitted with a speed adjuster If so it will be factory set at maximum and should not be changed FROST PRECAUTIONS If the...

Page 8: ...e and the MAX position By slightly reducing the flow of domestic water from the tap the delivery temperature of the water will be further increased This is of particular advantage in the winter for example to increase bath water temperature Also this will provide an added advantage of reducing the delay before hot water is obtained FACIA MOUNTED PROGRAMMER if fitted Your installer may have mounted...

Page 9: ... Domestic hot water demand indicator OFF No demand for domestic hot water ON Domestic hot water demand FLASHING FAST Air flow fault RSF Flue gas spillage OF five times per second Central heating and domestic hot water demand indicators BOTH FLASHING SLOW Overheat cut off once per second Flame detection indicator OFF Burner off ON Burner on Fig 2 Controls Operating switch Mains electricity indicato...

Page 10: ...facia mounted electronic programmer will retain its settings for about two weeks after which it will return to the factory set programme The display will disappear after approximately 12 hours A facia mounted mechanical programmer will require resetting once the operating switch has been set to O or the mains supply has been disconnected ELECTRICITY SUPPLY FAILURE If the electricity supply fails t...

Page 11: ...ting period of approximately 4 minutes Check that the flue terminal has not been obstructed or damaged If this condition continues to occur then call a service engineer FLUE SPILLAGE DEVICE OF ONLY The appliance is fitted with a device which detects the spillage of combustion products from the draught diverter In the event of the flue becoming wholly or partly blocked this device will cut the gas ...

Page 12: ...e Worcester Contact Centre on 08457 256206 Arrangements will be made for an engineer to call as soon as possible CALL OUT CHARGES All of our field service engineers are factory trained If you request a visit from an engineer and your appliance has been installed within the last 12 months no charge will be made for parts and or labour providing The appliance was commissioned correctly on installati...

Page 13: ... to ensure it continues to operate at peak efficiency and performance it is essential that your boiler receives regular competent servicing and annual maintenance checks beyond the initial 12 month guarantee period Regular service contracts can be arranged with your installer however if you have difficulty making a satisfactory arrangement simply contact Worcester on 01905 754624 for help ...

Page 14: ...99 OPERATING HOURS Mon Fri 7 00am to 8 00pm Sat 8 00am to 5 00pm Sun 9 00am to 12 00pm Please contact our UK Contact Centre number where our friendly oper ators will book your call with one of our team of nationwide engineers NOTE Please refer to our website for our bank holiday opening hours www worcester bosch co uk 14 SERVICE CENTRES ...

Page 15: ... of this appliance by third parties will not be accepted for payment by BBT 3 That the householder may be asked to prove the date of installation and that the appliance was correctly commissioned This information must then be documented in the Benchmark Gas Boiler Commissioning Checklist 4 That any product or part thereof returned for servicing under the guarantee must be accompanied by a claim st...

Page 16: ...RIAL NUMBER Copy the number off the Guarantee Card FOR YOUR OWN RECORD MODEL SERIAL NUMBER See identity label inside appliance casing TYPE SIZE DATE OF INSTALLATION CORGI CONTACT All CORGI Registered installers carry a CORGI ID card and have a registration number Both should be recorded in your central heating log book You can check your installer is CORGI Registered by calling CORGI on 01256 3723...

Reviews: