f

Do not operate the measuring tool in explosive environ-

ments, such as in the presence of flammable liquids, 

gases or dusts. 

Sparks can be created in the measuring 

tool which may ignite the dust or fumes.

Product Description and 

Specifications

Intended Use

The measuring tool is intended for determining and checking 

horizontal and vertical lines.
The measuring tool is suitable exclusively for operation in 

enclosed working sites.

Product Features

The numbering of the product features shown refers to the 

illustration of the measuring tool on the graphic page.

1

Exit opening for laser beam

2

Automatic levelling indicator

3

On/Off switch

4

Latch of battery lid

5

Battery lid

6

Contact surface

7

Laser warning label

8

Tripod mount 1/4"

9

Protective pouch

10

Laser viewing glasses*

11

Tripod*

* The accessories illustrated or described are not included as 

standard delivery.

Technical Data

Assembly

Inserting/Replacing the Battery

Alkali-manganese batteries are recommended for the meas-

uring tool.
To open the battery lid 

5

, press on the latch 

4

 and fold the bat-

tery lid up. Insert the batteries. When inserting, pay attention 

to the correct polarity according to the representation on the 

inside of the battery compartment.
Always replace all batteries at the same time. Only use batter-

ies from one brand and with the identical capacity.

f

Remove the batteries from the measuring tool when 

not using it for extended periods. 

When storing for ex-

tended periods, the batteries can corrode and discharge 

themselves.

Operation

Initial Operation

f

Protect the measuring tool against moisture and direct 

sun light.

f

Do not subject the measuring tool to extreme tempera-

tures or variations in temperature. 

As an example, do not 

leave it in vehicles for longer periods. In case of large varia-

tions in temperature, allow the measuring tool to adjust to 

the ambient temperature before putting it into operation.

f

Avoid heavy impact to or falling down of the measuring 

tool. 

Damage to the measuring tool can impair its accuracy. 

After heavy impact or shock, compare the laser line with a 

known horizontal or vertical reference line.

f

Switch the measuring tool off during transport. 

When 

switching off, the levelling unit, which can be damaged in 

case of intense movement, is locked.

Switching On and Off

To 

switch on

 the measuring tool, push the On/Off switch 

3

 to 

the 

“On”

 position. Immediately after switching on, the meas-

uring tool sends two laser beams out of the exit opening 

1

.

f

Do not point the laser beam at persons or animals and 

do not look into the laser beam yourself, not even from 

a large distance.

To 

switch off

 the measuring tool, slide the On/Off switch 

3

 to 

the 

“Off”

 position. When switching off, the levelling unit is 

locked.

f

Do not leave the switched on measuring tool unattended 

and switch the measuring tool off after use. 

Other per-

sons could be blinded by the laser beam.

Working with Automatic Levelling (see figures A–B)

Position the measuring tool on a level and firm support, hold 

it by the contact surfaces 

6

 against a vertical surface or attach 

it to a tripod 

11

.

After switching on, the levelling function automatically com-

pensates irregularities within the self-levelling range of 

±

4°. 

The levelling is finished as soon as the laser beams do not 

move any more. The indicator 

2

 lights up green.

Cross-line Laser

PCL 10

Article number

3 603 K08 1..

Working range to approx.

10 m

Levelling Accuracy

±

0.5 mm/m

Self-levelling range, typically

±

Levelling duration, typically

4 s

Operating temperature

+5 °C...+40 °C

Storage temperature

–20 °C...+70 °C

Relative air humidity, max.

90 %

Laser class

2

Laser type

635 nm, <1 mW

C

6

>10

Tripod mount

1/4"

Batteries

2 x 1.5 V LR06 (AA)

Operating life time, approx.

15 h

Weight according to 

EPTA-Procedure 01/2003

0.4 kg

Dimensions (length x width x height)

108 x 66 x 92 mm

Please observe the article number on the type plate of your measuring 
tool. The trade names of the individual measuring tools may vary.

OBJ_BUCH-693-003.book  Page 9  Friday, August 5, 2011  9:01 AM

Summary of Contents for WEU PLC 10

Page 1: ...etriebsanleitung en Original instructions fr Notice originale es Manual original pt Manual original it Istruzioni originali nl Oorspronkelijke gebruiksaanwijzing da Original brugsanvisning sv Bruksanvisning i original no Original driftsinstruks fi Alkuperäiset ohjeet el Ðñùôüôõðï ïäçãéþí ñÞóçò tr Orijinal işletme talimat ar fa ΕΎϤϴϠόΗ ϞϴϐθΘϟ ΔϴϠλϷ Ϡλ έΎ ίήσ ΎϤϨϫ έ OBJ_BUCH 693 003 book Page 1 Frid...

Page 2: ... Power Tools 1 619 929 J69 5 8 11 Off Off Off On On On Off Off Off On On On Off Off On On Off Off On On 1 7 6 6 8 2 3 4 9 10 11 5 6 2 607 990 031 PCL 10 OBJ_BUCH 693 003 book Page 3 Friday August 5 2011 9 01 AM ...

Page 3: ...929 J69 5 8 11 Bosch Power Tools 4 Off On Off On Off Off Off On On On Off On 4 4 Off Off Off On On On Off On 4 4 4 Off Off Off On On On Off On D C B A OBJ_BUCH 693 003 book Page 4 Friday August 5 2011 9 01 AM ...

Page 4: ... 5 Bosch Power Tools 1 619 929 J69 5 8 11 X X F E OBJ_BUCH 693 003 book Page 5 Friday August 5 2011 9 01 AM ...

Page 5: ...n Nicht mehr gebrauchsfähige Akkus Batterien können direkt abgegeben werden bei Deutschland Recyclingzentrum Elektrowerkzeuge Osteroder Landstraße 3 37589 Kalefeld Schweiz Batrec AG 3752 Wimmis BE Änderungen vorbehalten English Safety Notes Working safely with the measuring tool is possibleonlywhentheoperatingandsafety information are read completely and the in structions contained therein are str...

Page 6: ...putting it into operation f Avoid heavy impact to or falling down of the measuring tool Damage to the measuring tool can impair its accuracy After heavy impact or shock compare the laser line with a known horizontal or vertical reference line f Switch the measuring tool off during transport When switching off the levelling unit which can be damaged in case of intense movement is locked Switching O...

Page 7: ...lour perception Maintenance and Service Maintenance and Cleaning Store and transport the measuring tool only in the supplied protective pouch Keep the measuring tool clean at all times Do not immerse the measuring tool in water or other fluids Wipe off debris using a moist and soft cloth Do not use any cleaning agents or solvents Regularly clean the surfaces at the exit opening of the laser in par...

Page 8: ...1st Street Fort Bonifacio Global City 1634 Taguig City Philippines Tel 63 2 870 3871 Fax 63 2 870 3870 matheus contiero ph bosch com www bosch pt com ph Bosch Service Center 9725 27 Kamagong Street San Antonio Village Makati City Philippines Tel 63 2 899 9091 Fax 63 2 897 6432 rosalie dagdagan ph bosch com Malaysia Robert Bosch S E A Pte Ltd No 8A Jalan 13 6 G P O Box 10818 46200 Petaling Jaya Sel...

Reviews: