Troubleshooting
en
39
Fault
Cause and troubleshooting
"E:30 / -80"
The pump cap is not fully screwed in.
▶
Ensure that the pump cap is screwed in all the way
into the appliance. The handle on the pump cap
must be in a vertical position.
"E:36 / -25 / -26"
Drain pump is blocked.
▶
"Cleaning the drain pump", Page 35
"E:38 / -25 / -26"
Drain pump is blocked.
▶
if the fault is displayed again,
▶
"Cleaning the drain pump", Page 35
Inlet opening of the rubber gasket is blocked.
▶
"Cleaning the intake opening in the rubber gas-
The water pressure is low.
No remedial action possible.
The filter in the water inflow is blocked.
▶
Clean the water inflow filter.
The tap is turned off.
▶
Turn on the tap.
The water inlet hose is kinked or jammed.
▶
Ensure that the water inlet hose is not kinked or
jammed.
"E:35 / -10"
There is water in the base trough.
▶
Turn off the water tap.
▶
Call the after-sales service.
→
The appliance is leaking.
▶
Turn off the water tap.
▶
Call the after-sales service.
→
Voltage under-usage
symbol (double point).
The automatic voltage control system detects an un-
authorised voltage under-usage.
▶
No remedial action possible.
Note:
If the power supply is stable, the programme
continues to run as normal.
Voltage under-usage may cause extension of a pro-
gramme.
No remedial action possible.